{ "manufacturer": "Qubino", "manufacturerId": "0x0159", "label": "ZMNHID", "description": "Flush On/off Thermostat", "devices": [ { "productType": "0x0005", "productId": "0x0051" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Basic on/off Q1", "maxNodes": 16 }, "2": { "label": "Basic on/off I2", "maxNodes": 16 }, "3": { "label": "Basic on/off I3", "maxNodes": 16 }, "4": { "label": "High Temperature", "maxNodes": 16 }, "5": { "label": "Low Temperature", "maxNodes": 16 }, "6": { "label": "Default Reporting Group", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Input 1 Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Mono-Stable switch type (Push button)", "value": 0 }, { "label": "Bi-Stable switch type", "value": 1 } ] }, { "#": "2", "label": "Input 2 Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Mono-Stable switch type (Push button)", "value": 0 }, { "label": "Bi-Stable switch type", "value": 1 } ] }, { "#": "3", "label": "Input 3 Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Mono-Stable switch type (Push button)", "value": 0 }, { "label": "Bi-Stable switch type", "value": 1 } ] }, { "#": "4", "label": "Input 1 Contact Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open) input type", "value": 0 }, { "label": "NC (Normally close) input type", "value": 1 } ] }, { "#": "5", "label": "Input 2 Contact Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open) input type", "value": 0 }, { "label": "NC (Normally close) input type", "value": 1 } ] }, { "#": "6", "label": "Parameter No. 6", "description": "Input 3 contact type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open) input type", "value": 0 }, { "label": "NC (Normally close) input type", "value": 1 } ] }, { "#": "10", "label": "Parameter No. 10", "description": "Activate / deactivate functions ALL ON/ALL OFF", "valueSize": 2, "defaultValue": 255, "allowManualEntry": false, "options": [ { "label": "All on is not active all off is not active", "value": 0 }, { "label": "All on is not active all off active", "value": 1 }, { "label": "All on active all off is not active", "value": 2 }, { "label": "All on active, all off active", "value": 255 } ] }, { "#": "11", "label": "Parameter No. 11", "description": "I1 Functionality selection", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 1, "unsigned": true }, { "#": "12", "label": "Parameter No. 12", "description": "I2 Functionality selection", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "13", "label": "Parameter No. 13", "description": "I3 Functionality selection", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 32767, "unsigned": true }, { "#": "40", "label": "Parameter No. 40", "description": "Power reporting in Watts on Power change", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "42", "label": "Parameter No. 42", "description": "Power reporting in Watts by time interval for Q1", "valueSize": 2, "minValue": 0, "maxValue": 32767, "defaultValue": 0 }, { "#": "43", "label": "Parameter No. 43", "description": "Hysteresis On", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 1005, "unsigned": true }, { "#": "44", "label": "Parameter No. 44", "description": "Hysteresis Off", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 5, "unsigned": true }, { "#": "45", "label": "Parameter No. 45", "description": "Antifreeze", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 50, "unsigned": true }, { "#": "59", "label": "Parameter No. 59", "description": "Thermostat Mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Heat mode", "value": 0 }, { "label": "Cool mode", "value": 1 } ] }, { "#": "60", "label": "Parameter No. 60", "description": "Too low temperature limit", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 50, "unsigned": true }, { "#": "61", "label": "Parameter No. 61", "description": "Too high temperature limit", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 700, "unsigned": true }, { "#": "63", "label": "Parameter No. 63", "description": "Output Switch selection", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "When system is turned off the output is 0 V", "value": 0 }, { "label": "When system is turned off the output is 230 V", "value": 1 } ] }, { "#": "70", "label": "Input 1 Status on Delay", "description": "Switching reaction time on delay for I1", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "71", "label": "Input 1 Status Off Delay", "description": "Switching reaction time off delay for I1", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "72", "label": "Input 2 Status on Delay", "description": "Switching reaction time on delay for I2", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "73", "label": "Input 2 Status Off Delay", "description": "Switching reaction time off delay for I2", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "74", "label": "Input 3 Status on Delay", "description": "Switching reaction time on delay for I3", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "75", "label": "Input 3 Status Off Delay", "description": "Switching reaction time off delay for I3", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "100", "label": "Parameter No. 100", "description": "Enable / Disable Endpoint I1 or select Notification Type and Event", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "101", "label": "Parameter No. 101", "description": "Enable / Disable Endpoint I2 or select Notification Type and Event", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "102", "label": "Parameter No. 102", "description": "Enable / Disable Endpoint I3 or select Notification Type and Event", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "110", "label": "Parameter No. 110", "description": "Temperature sensor offset settings", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 32536, "unsigned": true }, { "#": "120", "label": "Parameter No. 120", "description": "Digital temperature sensor reporting", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 5 }, { "#": "121", "label": "Parameter No. 121", "description": "Digital temperature sensor / setpoint selector", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "122", "label": "Parameter No. 122", "description": "Node ID of external battery powered room sensor", "valueSize": 1, "minValue": 0, "maxValue": 254, "defaultValue": 0, "unsigned": true } ] }