{ "manufacturer": "Qubino", "manufacturerId": "0x0159", "label": "ZMNHBA", "description": "Flush 2 Relays", "devices": [ { "productType": "0x0002", "productId": "0x0001" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Basic on/off Q1", "maxNodes": 4 }, "2": { "label": "Basic on/off Q2", "maxNodes": 4 }, "3": { "label": "Default Reporting Group", "maxNodes": 4, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Input 1 Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Mono-Stable switch type (Push button)", "value": 0 }, { "label": "Bi-Stable switch type", "value": 1 } ] }, { "#": "2", "label": "Input 2 Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Mono-Stable switch type (Push button)", "value": 0 }, { "label": "Bi-Stable switch type", "value": 1 } ] }, { "#": "10", "label": "Activate / Deactivate Functions ALL ON/ALL OFF", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "All on is not active all off is not active", "value": 0 }, { "label": "All on is not active all off active", "value": 1 }, { "label": "All on active all off is not active", "value": 2 }, { "label": "All on active, all off active", "value": 255 } ] }, { "#": "11", "label": "Automatic Turning Off Relay Q1 After Set Time", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "12", "label": "Automatic Turning Off Relay Q2 After Set Time", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "30", "$import": "~/templates/master_template.json#state_after_power_failure_prev_off" }, { "#": "40", "label": "Power Reporting in Watts on Power Change for Q1", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "41", "label": "Power Reporting in Watts on Power Change for Q2", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "42", "label": "Power Reporting in Watts by Time Interval for Q1", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 300, "unsigned": true }, { "#": "43", "label": "Power Reporting in Watts by Time Interval for Q2", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 300, "unsigned": true } ] }