{ "manufacturer": "Qubino", "manufacturerId": "0x0159", "label": "ZMNHAA", "description": "Flush 1 Relay", "devices": [ { "productType": "0x0002", "productId": "0x0002" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Basic on/off - output Q", "maxNodes": 16 }, "2": { "label": "Basic on/off - input I2", "maxNodes": 16 }, "3": { "label": "Basic on/off - input I3", "maxNodes": 16 }, "4": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Input 1 Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Mono-Stable switch type (Push button)", "value": 0 }, { "label": "Bi-Stable switch type", "value": 1 } ] }, { "#": "2", "label": "Input 2 Contact Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open) input type", "value": 0 }, { "label": "NC (Normally close) input type", "value": 1 } ] }, { "#": "3", "label": "Input 3 Contact Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open) input type", "value": 0 }, { "label": "NC (Normally close) input type", "value": 1 } ] }, { "#": "10", "label": "Activate / Deactivate Functions ALL ON/ALL OFF", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "All on is not active all off is not active", "value": 0 }, { "label": "All on is not active all off active", "value": 1 }, { "label": "All on active all off is not active", "value": 2 }, { "label": "All on active, all off active", "value": 255 } ] }, { "#": "11", "label": "Automatic Turning Off Relay After Set Time", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "30", "$import": "~/templates/master_template.json#state_after_power_failure_prev_off" }, { "#": "40", "label": "Power Reporting in Watts on Percentage Change", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 3, "unsigned": true }, { "#": "42", "label": "Power Reporting in Watts on Power Change", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 300, "unsigned": true } ], "compat": { "commandClasses": { "add": { "Manufacturer Specific": { // Manufacturer Specific CC is supported, but comes back as version 0 "version": 1, "isSupported": true }, "Association": { // Association CC is supported, but comes back as version 0 "version": 1, "isSupported": true } } } } }