{ "manufacturer": "Nortek Security & Control LLC", "manufacturerId": "0x014f", "label": "WT00Z-1", "description": "3-Way Wall Accessory Switch", "devices": [ { "productType": "0x5457", "productId": "0x3033" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Controller", "maxNodes": 5, "isLifeline": true }, "2": { "label": "Associating Group 2", "maxNodes": 5 }, "3": { "label": "Associating Group 3", "maxNodes": 5 }, "4": { "label": "Associating Group 4", "maxNodes": 5 } }, "paramInformation": [ { "#": "2", "$import": "~/templates/master_template.json#base_enable_disable_inverted", "label": "Group 4: Send Reports", "defaultValue": 0 }, { "#": "3", "$import": "~/templates/master_template.json#led_indicator_two_options_inverted", "defaultValue": 0 }, { "#": "4", "$import": "~/templates/master_template.json#orientation" }, { "#": "5", "$import": "templates/config_template.json#ignore_dim_start" }, { "#": "7", "$import": "templates/config_template.json#dim_step_zwave" }, { "#": "8", "$import": "templates/config_template.json#dim_rate_zwave" }, { "#": "9", "$import": "templates/config_template.json#dim_step_manual" }, { "#": "10", "$import": "templates/config_template.json#dim_rate_manual" }, { "#": "11", "$import": "templates/config_template.json#dim_step_all" }, { "#": "12", "$import": "templates/config_template.json#dim_rate_all" }, { "#": "13", "$import": "~/templates/master_template.json#base_enable_disable_inverted", "label": "Group 4: Send Dimming Commands", "defaultValue": 0 }, { "#": "14", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Shade Control Group 2", "description": "Allow the switch to control shade devices" }, { "#": "15", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Shade Control Group 3", "description": "Allow the switch to control shade devices" }, { "#": "16", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Shade Control Group 1", "description": "Allow the switch to control shade devices" }, { "#": "19", "$import": "templates/config_template.json#led_indicator" }, { "#": "20", "label": "Poll: Minutes", "description": "Frequency that WT00Z-1 will poll first node in Group 1", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 2, "unsigned": true }, { "#": "21", "label": "Poll First Node in Group 1", "description": "Activate/Deactivate polling of first node in Group 1", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Do not poll first node in group", "value": 0 }, { "label": "Poll first node in group", "value": 1 } ] } ], "compat": { "mapBasicSet": "event" } }