{ "manufacturer": "wiDom", "manufacturerId": "0x0149", "label": "WDS", "description": "Universal Double Switch", "devices": [ { "productType": "0x1214", "productId": "0x0504" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true }, "2": { "label": "On/Off control (Switch 1)", "maxNodes": 8 }, "3": { "label": "Dimming control (Switch 1)", "maxNodes": 8 }, "4": { "label": "On/Off control (Switch 2)", "maxNodes": 8 }, "5": { "label": "Dimming control (Switch 2)", "maxNodes": 8 } }, "paramInformation": [ { "#": "1", "label": "Status Upon Receipt of 1 Click", "description": "Defines the status of the output O1/O2 after 1 Click", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "IN_OUT", "value": 0 }, { "label": "Toggle", "value": 1 }, { "label": "On", "value": 2 }, { "label": "Off", "value": 3 }, { "label": "Ignore", "value": 4 } ] }, { "#": "2", "label": "Status Upon Receipt of 2 Clicks", "description": "Defines the status of the output O1/O2 after 2 Clicks", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Toggle", "value": 1 }, { "label": "On", "value": 2 }, { "label": "Off", "value": 3 }, { "label": "Ignore", "value": 4 } ] }, { "#": "3", "label": "Type of Outputs", "description": "Defines how the outputs are controlled", "valueSize": 1, "minValue": 0, "maxValue": 39, "defaultValue": 0 }, { "#": "4", "label": "Number of Clicks That Control the Device", "description": "Defines the Clicks on the Switches that control associated devices", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Controlled by 1 click", "value": 1 }, { "label": "Controlled by 2 clicks", "value": 2 } ] }, { "#": "5", "label": "Level Used to Control Association Group 2 and 3", "valueSize": 1, "minValue": -1, "maxValue": 106, "defaultValue": 100 }, { "#": "6", "label": "Level Used to Control Association Group 4 and 5", "valueSize": 1, "minValue": -1, "maxValue": 106, "defaultValue": 100 }, { "#": "10", "label": "Timer to Switch OFF the Channel 1", "description": "Defines the time after which the Channel 1 is switched OFF", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "11", "label": "Timer to Switch OFF the Channel 2", "description": "Defines the time after which the Channel 2 is switched OFF", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "12", "label": "Timer to Switch ON the Channel 1", "description": "Defines the time after which the Channel 1 is switched ON", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "13", "label": "Timer to Switch ON the Channel 2", "description": "Defines the time after which the Channel 2 is switched ON", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32000, "defaultValue": 0, "readOnly": true }, { "#": "20", "label": "Status After Multi-Channel Basic Set Command", "description": "Defines how Basic Set commands controlling outputs", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "As received", "value": 1 }, { "label": "Ignore if on", "value": 2 }, { "label": "Ignore if off", "value": 3 }, { "label": "Ignore", "value": 4 } ] }, { "#": "21", "label": "Outputs Status Upon Receipt of A Basic Set Command", "description": "Define which channels are controlled by Basic Set command", "valueSize": 2, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Channel 1", "value": 1 }, { "label": "Both channels", "value": 3 } ] }, { "#": "60", "label": "Start-Up Status", "description": "Defines the status of the device following a restart.", "valueSize": 1, "defaultValue": 4, "allowManualEntry": false, "options": [ { "label": "OFF_OFF", "value": 0 }, { "label": "ON_OFF", "value": 1 }, { "label": "OFF_ON", "value": 2 }, { "label": "ON_ON", "value": 3 }, { "label": "Previous status", "value": 4 } ] }, { "#": "61", "label": "Configuration Reset", "description": "Defines which parameters should be reset to default values", "valueSize": 1, "defaultValue": 4, "allowManualEntry": false, "options": [ { "label": "Factory reset", "value": 0 }, { "label": "Associations reset", "value": 1 }, { "label": "Configurations reset", "value": 2 }, { "label": "Restart device", "value": 3 }, { "label": "Ignore", "value": 4 } ] }, { "#": "62", "label": "Type of External Switch", "description": "Defines the type of external switch connected to the device", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Ignore", "value": 0 }, { "label": "Button", "value": 1 }, { "label": "Switch", "value": 2 } ] } ] }