{ "manufacturer": "wiDom", "manufacturerId": "0x0149", "label": "DRY", "description": "Widom Smart Dry Contact", "devices": [ { "productType": "0x1214", "productId": "0x0900" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true }, "2": { "label": "1 Click", "maxNodes": 8 }, "3": { "label": "2 Clicks", "maxNodes": 8 }, "4": { "label": "3 Clicks", "maxNodes": 8 } }, "paramInformation": [ { "#": "1", "label": "Numbers of Clicks to Control the Load", "valueSize": 1, "minValue": 0, "maxValue": 7, "defaultValue": 7 }, { "#": "4", "label": "Value Used for Devices Belonging to Group 2", "description": "Value sent when the external switch receives 1 click. Allowable range: 0-99, 255", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "5", "label": "Value Used for Devices Belonging to Group 3", "description": "Value sent when the external switch receives 2 clicks. Allowable range: 0-99, 255", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "6", "label": "Value Used for Devices Belonging to Group 4", "description": "Value sent when external switch receives 3 clicks. Allowable range: 0-99, 255", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "10", "label": "Timer to Switch OFF the Relay", "description": "Defines the time after which the relay is switched OFF", "valueSize": 2, "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "11", "label": "Timer to Switch ON the Relay", "description": "Defines the time after which the relay is switched ON", "valueSize": 2, "minValue": 0, "maxValue": 32000, "defaultValue": 0 }, { "#": "15", "label": "Timer Scale", "description": "Defines the time unit used for parameters No.10 and No.11.", "valueSize": 2, "minValue": 1, "maxValue": 2, "defaultValue": 1, "writeOnly": true }, { "#": "20", "label": "One Click Scene Activation Set", "description": "Defines the Scene Activation Set value sent to the Lifeline group with 1 Click", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "21", "label": "Two Clicks Scene Activation Set", "description": "Defines the Scene Activation Set value sent to the Lifeline group with 2 Clicks", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "22", "label": "Three Clicks Scene Activation Set", "description": "Defines the Scene Activation Set value sent to the Lifeline group with 3 Clicks", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "60", "label": "Start-Up Status", "description": "Defines the status of the device following a restart", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "On", "value": 1 }, { "label": "Off", "value": 2 }, { "label": "Previous status", "value": 3 } ] }, { "#": "62", "label": "Type of External Switch", "description": "Defines the type of external switch connected to the device", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Ignore", "value": 0 }, { "label": "Button", "value": 1 }, { "label": "Switch", "value": 2 } ] } ] }