{ "manufacturer": "Z-Wave.Me", "manufacturerId": "0x0115", "label": "ZME_06433", "description": "Zwave.Me Dimmer Set Everlux", "devices": [ { "productType": "0x1000", "productId": "0x0002", "zwaveAllianceId": 19 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Association group 1", "description": "Single press and hold of up/down buttons (max. nodes in group: 14)", "maxNodes": 14 }, "2": { "label": "Association group 2", "maxNodes": 14 }, "3": { "label": "Association group 3", "description": "Send Reports on blind state change", "maxNodes": 14, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "LED Mode", "description": "Set LED indication mode", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Show switch state", "value": 1 }, { "label": "Night mode (Inverted switch state)", "value": 2 }, { "label": "Operated by Indicator Command Class", "value": 3 } ] }, { "#": "2", "label": "Automatically Switch Off After", "description": "If not zero, automatically switch off after a user defined time", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "3", "label": "What to Do on RF Off Command", "description": "Defines how to interpret RF Off command.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Switch off", "value": 0 }, { "label": "Ignore", "value": 1 }, { "label": "Switch on", "value": 2 } ] }, { "#": "4", "label": "Ignore Start Level", "description": "ignore start level in StartLevelChange", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "No", "value": 0 }, { "label": "Yes", "value": 1 } ] }, { "#": "5", "label": "Dimming Speed", "description": "Time to dim on button presses", "valueSize": 1, "unit": "10 ms", "minValue": 0, "maxValue": 255, "defaultValue": 30, "unsigned": true }, { "#": "6", "label": "Dimming Long Speed", "description": "Time to dim on button holds and StartLevelChange", "valueSize": 1, "unit": "seconds", "minValue": 1, "maxValue": 255, "defaultValue": 3, "unsigned": true }, { "#": "7", "label": "Set Maximum Light Level on On Click", "description": "set action on ON command", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No", "value": 0 }, { "label": "If already on", "value": 1 }, { "label": "Always", "value": 2 } ] }, { "#": "11", "label": "Invert Buttons", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No", "value": 0 }, { "label": "Yes", "value": 1 } ] }, { "#": "13", "label": "Action on Button Single Press or Hold", "description": "Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Switch on, off and dim using Basic Set", "value": 1 }, { "label": "Switch all on/off", "value": 2 } ] }, { "#": "14", "label": "Action on Button Double Press or Hold", "description": "Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. This will introduce a small delay for single click commands", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disabled (Don't wait for double click, default)", "value": 0 }, { "label": "Switch on, off and dim using Basic Set", "value": 1 }, { "label": "Switch all on/off", "value": 2 } ] } ] }