{ "manufacturer": "Vision Security", "manufacturerId": "0x0109", "label": "ZP3113-7", "description": "4 in 1 PIR Sensor", "devices": [ { "productType": "0x2021", "productId": "0x2112", "zwaveAllianceId": [4099, 4314, 4315] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true }, "2": { "label": "On/Off", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "$import": "~/templates/master_template.json#temperature_scale_celsius_fahrenheit" }, { "#": "2", "label": "Temperature Reporting Threshold", "valueSize": 1, "unit": "0.1 °C", "minValue": 1, "maxValue": 50, "defaultValue": 30 }, { "#": "3", "label": "Humidity Reporting Threshold", "description": "Allowable range: 5%-50%", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 50, "defaultValue": 20, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "4", "label": "Light Reporting Threshold", "description": "Allowable range: 5%-50%", "valueSize": 1, "minValue": 0, "maxValue": 50, "defaultValue": 25, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "5", "label": "Motion Trigger Interval", "valueSize": 1, "unit": "minutes", "minValue": 1, "maxValue": 127, "defaultValue": 3 }, { "#": "6", "label": "Motion Sensitivity", "valueSize": 1, "minValue": 1, "maxValue": 7, "defaultValue": 4 }, { "#": "7", "label": "LED Indicator", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Always off", "value": 1 }, { "label": "Flash - PIR/Temperature", "value": 2 }, { "label": "PIR only", "value": 3 } ] }, { "#": "8", "label": "Message Failure Retry Limit", "valueSize": 1, "minValue": 0, "maxValue": 10, "defaultValue": 3 } ], "metadata": { "inclusion": "For “Inclusion” in (adding to) a network: To add the ZP3113 to your Z-Wave network (inclusion), place your Z-Wave primary controller into inclusion mode. Press the Program Switch of ZP3113 once for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZP3113 will go to sleep after 30 seconds. The LED indicator will be flashing while the inclusion is continued", "exclusion": "For “Exclusion” from (removing from) a network: To remove the ZP3113 from your Z-Wave network (exclusion), place your Z-Wave primary controller into “exclusion” mode, and following its instruction to delete the ZP3113 to your controller. Press the Program Switch of ZP3113 once to be excluded.", "reset": "Factory Default Reset: \nRemove cover to triggered tamper switch, LED flash once & send out Alarm Report. Press Program Switch 10 times within 10 seconds, ZP3113 will send the “Device Reset Locally Notification” command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4314/ZP3113-7%204%20in%201%20PIR%20(Z-Wave%20certified)%20-%2020211004.pdf" } }