{ "manufacturer": "Vision Security", "manufacturerId": "0x0109", "label": "ZL7435-5", "description": "In-Wall Two Relay", "devices": [ { "productType": "0x2017", "productId": "0x1719", "zwaveAllianceId": 1367 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Button Mode Switching", "description": "This parameter sets the mode for the wall switch inputs", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Switch mode", "value": 0 }, { "label": "Toggle mode", "value": 1 } ] } ], "metadata": { "inclusion": "For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZL 7435EU-5 to your controller. To get in the “inclusion” mode, the distance between module and controller is suggested to be in one meter. \nPress 3 times within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be included.", "exclusion": "For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZL 7435EU-5 from your controller. Press 3 times within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be excluded.", "reset": "Factory Default Reset: Power off first, press Program Switch and power on till 10 seconds, ZL7435EU-5 will send the “Device Reset Locally Notification” command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1367/ZL7435-5%20In-Wall%20Switch%20-%202%20Relays_20141205.pdf" } }