{ "manufacturer": "Vision Security", "manufacturerId": "0x0109", "label": "ZB5311US-5", "description": "Glass Break Detector", "devices": [ { "productType": "0x202f", "productId": "0x2f01", "zwaveAllianceId": 3819 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "metadata": { "inclusion": "For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZB5311-5 to your controller. To get in the “inclusion” mode, press the Program Switch of ZB5311-5 once for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZB5311-5 will go to sleep after 30 seconds. After inclusion successfully, the Green LED will be solid on for 0.5 second", "exclusion": "For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZB5311-5 from your controller. Press the Program Switch of ZB5311-5 once to be excluded, the Green LED will flash 5 times quickly after successful exclusion.\nNote: All user and network settings will be cleared and the device reset to factory defaults when the device is excluded.", "reset": "Factory Default Reset: Long press the program switch up to 10 seconds to send the “Device Reset Locally Notification” command and reset to the factory default. The Green LED will flash 5 times quickly after finishing the Factory Default Reset.\n(Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3819/ZB5311-5%20Glass%20Break%20Detector%20Manual%20(RD%20%20FCC%20Checked)_20200304.pdf" } }