{ "manufacturer": "Radio Thermostat Company of America (RTC)", "manufacturerId": "0x0098", "label": "CT100 Plus", "description": "Z-Wave Thermostat", "devices": [ { "productType": "0x6402", "productId": "0x0100" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Temperature Reporting Threshold", "description": "Reporting threshold for changes in the ambient temperature", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "0.5 °F", "value": 1 }, { "label": "1.0 °F", "value": 2 }, { "label": "1.5 °F", "value": 3 }, { "label": "2.0 °F", "value": 4 } ] }, { "#": "2", "label": "HVAC Settings", "description": "Configured HVAC settings", "valueSize": 4, "minValue": 0, "maxValue": 0, "defaultValue": 0, "readOnly": true }, { "#": "3", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Utility Lock", "description": "Prevents setpoint changes at thermostat" }, { "#": "4", "label": "Power Status", "description": "C-Wire / Battery Status", "valueSize": 1, "minValue": 0, "maxValue": 0, "defaultValue": 0, "readOnly": true }, { "#": "5", "label": "Humidity Reporting Threshold", "description": "Reporting threshold for changes in the relative humidity", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "3 %rH", "value": 1 }, { "label": "5 %rH", "value": 2 }, { "label": "10 %rH", "value": 3 } ] }, { "#": "6", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Auxiliary/Emergency Heat", "description": "Enables or disables auxiliary / emergency heating" }, { "#": "7", "label": "Thermostat Swing Temperature", "description": "Variance allowed from setpoint to engage HVAC", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "0.5 °F", "value": 1 }, { "label": "1.0 °F", "value": 2 }, { "label": "1.5 °F", "value": 3 }, { "label": "2.0 °F", "value": 4 }, { "label": "2.5 °F", "value": 5 }, { "label": "3.0 °F", "value": 6 }, { "label": "3.5 °F", "value": 7 }, { "label": "4.0 °F", "value": 8 } ] }, { "#": "8", "label": "Thermostat Diff Temperature", "description": "Configures additional stages", "valueSize": 1, "defaultValue": 4, "allowManualEntry": false, "options": [ { "label": "2.0 °F", "value": 4 }, { "label": "4.0 °F", "value": 8 }, { "label": "6.0 °F", "value": 12 } ] }, { "#": "9", "label": "Thermostat Recovery Mode", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Fast", "value": 1 }, { "label": "Economy", "value": 2 } ] }, { "#": "10", "label": "Temperature Reporting Filter", "description": "Upper/Lower bounds for thermostat temperature reporting", "valueSize": 4, "minValue": 0, "maxValue": 124, "defaultValue": 124 }, { "#": "11", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Simple UI Mode", "defaultValue": 1 }, { "#": "12", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Multicast" } ] }