{ "manufacturer": "BeNext", "manufacturerId": "0x008a", "label": "plugInDimmer", "description": "Plug-In Dimmer", "devices": [ { "productType": "0x0018", "productId": "0x0100" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Group 1", "description": "Receives BASIC SET commands", "maxNodes": 8 }, "2": { "label": "Group 2", "description": "Receives METER and MULTILEVEL_SWITCH commands", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Reset to Factory Settings", "description": "Set all configuration values to default values (factory settings).", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Dimming" }, { "#": "6", "label": "Maximum Powerload", "valueSize": 2, "minValue": 25, "maxValue": 150, "defaultValue": 125 }, { "#": "7", "label": "Dimming Speed", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 3, "unsigned": true }, { "#": "8", "label": "Fading Up Speed", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "11", "label": "Auto Meter Report: Percentage", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "12", "label": "Auto Meter Report: Watt", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "13", "label": "Auto Meter Report: Time", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true }, { "#": "14", "label": "Last Known Status", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "15", "label": "Fading Down Speed", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true } ] }