{ "manufacturer": "BeNext", "manufacturerId": "0x008a", "label": "Heating Control", "description": "Thermostat for Controlling the Opentherm Protocol", "devices": [ { "productType": "0x0021", "productId": "0x0102" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Group 1", "description": "Unsolicited reports", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Set to Default", "description": "Set all configuration values to default values (factory settings)", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Reset", "value": 255 } ] }, { "#": "2", "label": "Data Request Interval", "description": "Interval of updating data from thermostat and boiler", "valueSize": 1, "unit": "seconds", "minValue": 1, "maxValue": 255, "defaultValue": 14, "unsigned": true }, { "#": "3", "label": "T Room Update Difference", "description": "Difference of temperature before new update", "valueSize": 1, "unit": "0.1 °C", "minValue": 1, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "4", "label": "T Setpoint Update Difference", "description": "Difference in setpoint before new update", "valueSize": 1, "unit": "0.1 °C", "minValue": 1, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "5", "label": "Unsolicited CRC", "description": "CRC-16 encapulation", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Off", "value": 0 }, { "label": "On", "value": 255 } ] }, { "#": "6", "label": "Type of 'special' Thermostat", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No special", "value": 0 }, { // eslint-disable-next-line @zwave-js/consistent-config-string-case "label": "Remeha Celcia 20", "value": 1 }, { "label": "Honeywell (Rounded temperatures)", "value": 2 } ] }, { "#": "7", "$import": "~/templates/master_template.json#base_enable_disable_255", "label": "Status Auto Report", "description": "Status auto report boiler/thermostat report." }, { "#": "9", "$import": "~/templates/master_template.json#base_enable_disable_255", "label": "Thermostat Schedule" }, { "#": "11", "label": "Readout Manual Setpoint Thermostat", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Readout off", "value": 0 }, { "label": "Readout on", "value": 255 } ] } ] }