{ "manufacturer": "AEON Labs", "manufacturerId": "0x0086", "label": "ZW074", "description": "MultiSensor Gen5", "devices": [ { "productType": "0x0002", "productId": "0x004a", "zwaveAllianceId": 1170 }, { "productType": "0x0102", "productId": "0x004a", "zwaveAllianceId": 1163 }, { "productType": "0x0202", "productId": "0x004a", "zwaveAllianceId": 1169 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "2", "$import": "templates/aeotec_template.json#wake_up_10_minutes" }, { "#": "3", "$import": "templates/aeotec_template.json#motion_timeout" }, { "#": "4", "$import": "templates/aeotec_template.json#enable_motion_sensor" }, { "#": "5", "$import": "templates/aeotec_template.json#motion_report_type" }, { "#": "40", "$import": "templates/aeotec_template.json#selective_reporting" }, { "#": "41", "label": "Temperature Change to Induce Automatic Report", "description": "Formula: (256 * integer + fraction). Ex: 5.0% threshold = (256 * 5) + 0 = 1280", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 256, "unsigned": true }, { "#": "42", "label": "Humidity Change to Induce Automatic Report", "description": "Formula: (256 * integer + fraction). Ex: 5.0% threshold = (256 * 5) + 0 = 1280", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 1280, "unsigned": true }, { "#": "43", "label": "Luminance Change to Induce Automatic Report", "description": "Formula: (256 * value). Ex: 100 lux threshold = (256 * 100) = 25600", "valueSize": 2, "minValue": 0, "maxValue": 1000, "defaultValue": 100 }, { "#": "44", "label": "Battery Change to Induce Automatic Report", "description": "Formula: (256 * integer + fraction). Ex: 5.0% threshold = (256 * 5) + 0 = 1280", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 1280, "unsigned": true }, { "#": "46", "$import": "templates/aeotec_template.json#low_temp_alarm" }, { "#": "101[0x01]", "$import": "templates/aeotec_template.json#auto_report_group1_battery" }, { "#": "101[0x20]", "$import": "templates/aeotec_template.json#auto_report_group1_temp" }, { "#": "101[0x40]", "$import": "templates/aeotec_template.json#auto_report_group1_humidity" }, { "#": "101[0x80]", "$import": "templates/aeotec_template.json#auto_report_group1_luminance" }, { "#": "102[0x01]", "$import": "templates/aeotec_template.json#auto_report_group2_battery" }, { "#": "102[0x20]", "$import": "templates/aeotec_template.json#auto_report_group2_temp" }, { "#": "102[0x40]", "$import": "templates/aeotec_template.json#auto_report_group2_humidity" }, { "#": "102[0x80]", "$import": "templates/aeotec_template.json#auto_report_group2_luminance" }, { "#": "103[0x01]", "$import": "templates/aeotec_template.json#auto_report_group3_battery" }, { "#": "103[0x20]", "$import": "templates/aeotec_template.json#auto_report_group3_temp" }, { "#": "103[0x40]", "$import": "templates/aeotec_template.json#auto_report_group3_humidity" }, { "#": "103[0x80]", "$import": "templates/aeotec_template.json#auto_report_group3_luminance" }, { "#": "111", "$import": "templates/aeotec_template.json#auto_report_interval_group1", "defaultValue": 1800 }, { "#": "112", "$import": "templates/aeotec_template.json#auto_report_interval_group2", "defaultValue": 1800 }, { "#": "113", "$import": "templates/aeotec_template.json#auto_report_interval_group3", "defaultValue": 1800 }, { "#": "252", "$import": "templates/aeotec_template.json#lock_configuration" }, { "#": "255", "$import": "templates/aeotec_template.json#factory_reset_exclude" } ], "compat": { "forceNotificationIdleReset": true }, "metadata": { "inclusion": "Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button that you can find in the back of the product", "exclusion": "Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button that you can find in back of the product", "reset": "Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1163/Instructions%20-%20MultiSensor%20Gen5%20MCert1.pdf" } }