{ "manufacturer": "Fakro", "manufacturerId": "0x0085", "label": "ZWS12", "description": "Chain Actuator - Window Opener", "devices": [ { "productType": "0x0002", "productId": "0x0011", "zwaveAllianceId": 2477 }, { "productType": "0x0002", "productId": "0x0111" }, { "productType": "0x0002", "productId": "0x0116" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "7", "label": "Motor Speed I", "valueSize": 1, "minValue": 1, "maxValue": 4, "defaultValue": 2 }, { "#": "8", "label": "Motor Speed II (Rain Sensor)", "valueSize": 1, "minValue": 1, "maxValue": 4, "defaultValue": 2 }, { "#": "12", "$import": "templates/fakro_template.json#calibration" }, { "#": "13", "$import": "templates/fakro_template.json#shutter_response_to_basic_set_0xff" }, { "#": "15", "label": "Close After Time", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 120, "defaultValue": 0 } ], "metadata": { "inclusion": "Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power actuator (OFF-ON-OFFON-OFF-ON) causes the introduction of actuator to Autoinclusion mode.\nPlease note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an actuator to any Z-Wave controller running in the Include procedure.\n\nInclude - This function allow you to add actuator to the network Z-Wave.\nFollow the procedure adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the actuator for 1 second", "exclusion": "Exclude - This function allow you to remove actuator from the network Z-Wave. Follow the procedure removing device from the network Z-Wave\naccording to user manual supplied with the product. Then, press the\nprogramming button P on the actuator for 1 second. Function removes\ninformation only about network Z-Wave", "reset": "Device Reset Locally – This function allows you to reset the Z-Wave\nnetwork without the use of Z-Wave controller. Press 5 times the\nprogramming button P fast, the actuator was removed from the Z-Wave\nnetwork, restore the default parameters, name and locations. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2477/170511%20ZWS12%20User%20Manual.pdf" } }