{ "manufacturer": "Secure Meters (UK) Ltd.", "manufacturerId": "0x0059", "label": "SWM301", "description": "Z-Wave Module for Water Meter", "devices": [ { "productType": "0x000f", "productId": "0x0001" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Meter reading", "description": "Group receiving meter readings", "maxNodes": 2, "isLifeline": true }, "2": { "label": "low battery", "description": "Group receiving battery warnings", "maxNodes": 2, "isLifeline": true }, "3": { "label": "Temperature and low temp alarm", "description": "Group receiving temperature", "maxNodes": 2, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Meter Register Offset", "description": "current meter reading", "valueSize": 4, "unit": "Litre", "minValue": 0, "maxValue": 99999999, "defaultValue": 0 }, { "#": "2", "label": "Meter Reading Reporting Intervals", "description": "how often meter reading is sent", "valueSize": 2, "unit": "minutes", "minValue": 1, "maxValue": 10000, "defaultValue": 1440 }, { "#": "3", "label": "Delta Config for Meter Reading", "description": "min. delta for automatic report", "valueSize": 2, "unit": "Litre", "minValue": 0, "maxValue": 10000, "defaultValue": 0 }, { "#": "4", "label": "Mechanical Meter Serial Number", "valueSize": 4, "minValue": 0, "maxValue": 0, "defaultValue": 0 }, { "#": "5", "label": "Temperature Monitor on / Off", "description": "enable temperature monitor", "valueSize": 1, "unit": "Boolean", "minValue": 0, "maxValue": 1, "defaultValue": 0 }, { "#": "6", "label": "Temperature Delta", "description": "change in temperature for report", "valueSize": 1, "unit": "deg. Celsius", "minValue": 0, "maxValue": 30, "defaultValue": 0 }, { "#": "7", "label": "Temperature Alarm Threshold", "description": "temperature triggering alarm", "valueSize": 1, "unit": "deg. Celsius", "minValue": 0, "maxValue": 40, "defaultValue": 0 } ] }