{ "manufacturer": "Secure Meters (UK) Ltd.", "manufacturerId": "0x0059", "label": "SIR 321", "description": "RF Countdown Timer", "devices": [ { "productType": "0x0010", "productId": "0x0001" }, { "productType": "0x0010", "productId": "0x0002", "zwaveAllianceId": 1012 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Group 1", "maxNodes": 4, "isLifeline": true }, "2": { "label": "Group 2", "maxNodes": 4, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Fail Save Timer", "description": "Enable/Disable the Fail save timer", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "2", "label": "Temperature Scale", "description": "Set the Temperature scale to Celsius", "valueSize": 2, "unit": "°C", "minValue": 0, "maxValue": 127, "defaultValue": 0 }, { "#": "3", "label": "Temperature Reporting Intervals", "description": "Define the time interval for the temperature report that is sent.", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 0 }, { "#": "4", "label": "Delta Configuration Temperature Reporting", "description": "Set the delta-configuration of the temperature report in Celsius or Fahrenheit", "valueSize": 2, "unit": "°C", "minValue": 0, "maxValue": 100, "defaultValue": 0 }, { "#": "5", "label": "Temperature Cutoff", "description": "Set the Cutoff in Celsius", "valueSize": 2, "unit": "°C", "minValue": 0, "maxValue": 1000, "defaultValue": 0 } ] }