{ "manufacturer": "Secure Meters (UK) Ltd.", "manufacturerId": "0x0059", "label": "C17-ZW", "description": "7 Day Room Thermostat", "devices": [ { "productType": "0x0004", "productId": "0x0001", "zwaveAllianceId": [1740, 864] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Reports", "maxNodes": 1, "isLifeline": true }, "2": { "label": "Control", "maxNodes": 4 } }, "paramInformation": [ { "#": "1", "label": "Temperature Scale", "description": "Controls the temperature sensor scale", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Celsius", "value": 0 }, { "label": "Kelvin", "value": 255 } ] }, { "#": "2", "label": "Lower Temperature Limit", "description": "Defines the minimum temperature. Steps are 1C", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "3", "label": "Upper Temperature Limit", "description": "Defines the maximum temperature. Steps are 1C", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "4", "label": "Delta T", "description": "Defines the temperature steps of the heating control", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 5, "unsigned": true } ] }