{ "manufacturer": "Q-light", "manufacturerId": "0x0433", "label": "Zerodim", "description": "Q-Light Zerodim", "devices": [ { "productType": "0x0003", "productId": "0x000d" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true }, "2": { "label": "On/Off (rotary knob)", // Mirror of endpoint 1, group 2 "maxNodes": 5 }, "3": { "label": "Dimmer (rotary knob)", // Mirror of endpoint 1, group 3 "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "label": "Minimum Brightness Level", "description": "Set the desired value from 1 to 98% for the minimum dim level that the dimmer is restricted to, the dimmer will not go lower than the value set here.", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 98, "defaultValue": 10 }, { "#": "2", "label": "Maximum Brightness Level", "description": "Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to; the dimmer will not go higher than the value set here.", "valueSize": 1, "unit": "%", "minValue": 2, "maxValue": 99, "defaultValue": 99 }, { "#": "3", "label": "Automatic Control - Dimming Step Size", "description": "This parameter defines the percentage value of dimming step during the automatic control.", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "4", "label": "Automatic Control - Time of A Dimming Step", "description": "This parameter defines the time of single dimming step set in parameter 3 during the automatic control.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "5", "label": "Manual Control - Dimming Step Size", "description": "This parameter defines the percentage value of dimming step during the manual control.", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "6", "label": "Manual Control - Time of A Dimming Step", "description": "This parameter defines the time of single dimming step setin parameter 5 during the manual control.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "7", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "8", "label": "Scene ID Set", "description": "Scene ID is set by this configuration. Note: The actual action of each SCENE ID are set by SCENE_ACTUATOR_CONF(0x26) command.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "9", "label": "Auto-Off Timer", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] } ] }