{ "manufacturer": "Q-light", "manufacturerId": "0x0433", "label": "Z-Wave Puck", "description": "Q-Light Puck", "devices": [ { "productType": "0x0003", "productId": "0x0005" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true }, "2": { "label": "On/Off(S1) - Basic command", // Mirror of endpoint 1, group 2 "maxNodes": 5 }, "3": { "label": "Dimmer(S1) - Multilevel switch command", // Mirror of endpoint 1, group 3 "maxNodes": 5 }, "4": { "label": "On/Off(S2) - Basic command", // Mirror of endpoint 2, group 2 "maxNodes": 5 }, "5": { "label": "Dimmer(S2) - Multilevel switch command", // Mirror of endpoint 2, group 3 "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "label": "Minimum Brightness Level", "description": "Set the desired value from 1 to 98% for the minimum dim level that the dimmer is restricted to, the dimmer will not go lower than the value set here.", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 98, "defaultValue": 15 }, { "#": "2", "label": "Maximum Brightness Level", "description": "Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to, the dimmer will not go higher than the value set here.", "valueSize": 1, "unit": "%", "minValue": 2, "maxValue": 99, "defaultValue": 99 }, { "#": "3", "label": "Automatic Control - Dimming Step Size", "description": "This parameter defines the percentage value of dimming step during the automatic control.", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "4", "label": "Automatic Control - Time of A Dimming Step", "description": "This parameter defines the time of single dimming step set in parameter 3 during the automatic control.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "5", "label": "Manual Control - Dimming Step Size", "description": "This parameter defines the percentage value of dimming step during the manual control.", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "6", "label": "Manual Control - Time of A Dimming Step", "description": "This parameter defines the time of single dimming step setin parameter 5 during the manual control.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "7", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "8", "label": "Switch Type", "description": "Choose between momentary, ON/OFF and roller blind switch. Available settings: 0 – momentary (Push) switch. 1 – ON/OFF switch. 2– roller blind switch-two switches operate the device(S1 to brighter, S2 to dim", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Momentary (Push) switch", "value": 0 }, { "label": "On/Off switch", "value": 1 }, { "label": "Roller blind switch-two switches operate the device(S1 to brighter, S2 to dim)", "value": 2 } ] }, { "#": "9", "label": "Switch Functionality of S1 and S2", "description": "Set the desired value from 0 to 1 to turn on/off the memory function. Setting this value to 0 turns off the dimmer's Memory function. Setting this value to 1 turns on the dimmer's Memory function.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Standard mode", "value": 0 }, { "label": "S1 operates as S2, S2 operates as S1", "value": 1 } ] }, { "#": "10", "label": "S1 Scene ID Set", "description": "When you press S1 five times,the light is dimmed to the brightness set in Scene ID 3 . S1 Scene ID is set by this configuration. Note: The actual action of each SCENE ID are set by SCE-NE_ACTUATOR_CONF(0x26) command.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "11", "label": "S2 Scene ID Set", "description": "When you press S1 five times,the light is dimmed to the brightness set in Scene ID 5. S2 Scene ID is set by this configuration. Note: The actual action of each SCENE ID are set by SCE-NE_ACTUATOR_CONF(0x26) command.", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 2, "unsigned": true }, { "#": "12", "label": "Auto-Off Timer", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] } ] }