{ // Device is rebranded Shenzhen Neo NAS-WR01ZE "manufacturer": "Keemple", "manufacturerId": "0x041a", "label": "KP-SO-02", "description": "Smart Socket", "devices": [ { "productType": "0x0200", "productId": "0x0008" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "2", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Button", "defaultValue": 1 }, { "#": "3", "$import": "~/templates/master_template.json#enable_led_indicator", "defaultValue": 1 }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Auto-Off" }, { "#": "5", "label": "Auto-Off Delay", "description": "Delay time after the plug is switched off", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 32767, "defaultValue": 120 }, { "#": "6", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Meter Reports" }, { "#": "7", "label": "Meter Report Interval", "valueSize": 2, "unit": "seconds", "minValue": 30, "maxValue": 32767, "defaultValue": 300 }, { "#": "8", "label": "Overcurrent Protection Threshold", "description": "Threshold at which the plug enters overcurrent protection mode", "valueSize": 1, "unit": "A", "minValue": 1, "maxValue": 16, "defaultValue": 16 }, { "#": "9", "label": "Current Report Threshold", "description": "Change in current consumption that triggers a report", "valueSize": 2, "unit": "0.01 A", "minValue": 1, "maxValue": 1600, "defaultValue": 50 }, { "#": "10", "label": "Overcurrent Alarm Threshold", "description": "Threshold at which the plug sends an overcurrent notification", "valueSize": 1, "unit": "A", "minValue": 1, "maxValue": 16, "defaultValue": 13 } ], "metadata": { "comments": { "level": "warning", "text": "This device is buggy and sends large negative Meter Reports from time to time." } } }