{ "manufacturer": "Inteset", "manufacturerId": "0x039a", "label": "INT-SMMD-N1", "description": "Inteset PIR Motion Sensor", "devices": [ { "productType": "0x0003", "productId": "0x0106" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Motion Sensitivity", "description": "Higher values = lower sensitivity and lower range.", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 3 }, { "#": "2", "label": "Motion Window Time", "description": "The amount of time the moves specified in parameter #3 need to take place in for the sensor to report motion. Higher values = more sensitive.", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "4s", "value": 0 }, { "label": "8s", "value": 1 }, { "label": "12s", "value": 2 }, { "label": "16s", "value": 3 } ] }, { "#": "3", "label": "Pulse Count", "description": "Number of moves required for the sensor to report motion. Higher values = less sensitive.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "1", "value": 0 }, { "label": "2", "value": 1 }, { "label": "3", "value": 2 }, { "label": "4", "value": 3 } ] }, { "#": "4", "label": "Motion Blind Time", "description": "The amount of time the sensor will not report motion after it has reported motion.", "valueSize": 1, "defaultValue": 15, "allowManualEntry": false, "options": [ { "label": "0.5s", "value": 0 }, { "label": "1s", "value": 1 }, { "label": "1.5s", "value": 2 }, { "label": "2s", "value": 3 }, { "label": "2.5s", "value": 4 }, { "label": "3s", "value": 5 }, { "label": "3.5s", "value": 6 }, { "label": "4s", "value": 7 }, { "label": "4.5s", "value": 8 }, { "label": "5s", "value": 9 }, { "label": "5.5s", "value": 10 }, { "label": "6s", "value": 11 }, { "label": "6.5s", "value": 12 }, { "label": "7s", "value": 13 }, { "label": "7.5s", "value": 14 }, { "label": "8s", "value": 15 } ] }, { "#": "5", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Enable Motion Sensor", "defaultValue": 1 }, { "#": "6", "label": "Motion Clear Time", "description": "How long the sensor will wait before reporting no motion", "valueSize": 2, "unit": "seconds", "minValue": 10, "maxValue": 3600, "defaultValue": 30 }, { "#": "7", "$import": "~/templates/master_template.json#base_enable_disable", "label": "LED Indicator: Blink on Motion", "defaultValue": 1 }, { "#": "8", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Binary Sensor Reports" }, { "#": "9", "label": "Group 2: Basic Set Level", "valueSize": 1, "defaultValue": 100, "allowManualEntry": false, "options": [ { "label": "Off (0x00)", "value": 0 }, { "label": "On (0xff)", "value": 100 } ] }, { "#": "10", "label": "Brightness Measuring Interval", "valueSize": 2, "unit": "seconds", "minValue": 30, "maxValue": 3600, "defaultValue": 180 }, { "#": "11", "label": "Brightness Change Report Threshold", "valueSize": 1, "minValue": 1, "maxValue": 127, "defaultValue": 50 }, { "#": "12", "label": "Night/Day Brightness Threshold", "valueSize": 1, "minValue": 1, "maxValue": 127, "defaultValue": 50 }, { "#": "13", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Report Motion Only At Night", "description": "When enabled, the sensor will report motion only when the ambient brightness is below the value set in parameter #12." }, { "#": "14", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Repeat Motion Event While Active" }, { "#": "99", "label": "Brightness Calibration Factor", "valueSize": 2, "unit": "1/1000", "minValue": 1, "maxValue": 65535, "defaultValue": 1000, "unsigned": true } ], "metadata": { "wakeup": "Press the button briefly", "inclusion": "Press the button 3 times within 1.5s to enter inclusion mode.", "exclusion": "Press the button 3 times within 1.5s", "reset": "Press and hold the button for 10s until LED light is on, then release the button.", "manual": "http://downloads.inteset.com/Motion2In1ManualS2.pdf" } }