{ "manufacturer": "COMAP", "manufacturerId": "0x0329", "label": "LIZY0005", "description": "In-Wall On/Off Switch Module", "devices": [ { "productType": "0x0004", "productId": "0x0008", "zwaveAllianceId": 2213 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Basic Set Command Value", "description": "The basic set value", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "2", "label": "Delaying Time to Report to Group 1", "valueSize": 1, "unit": "seconds", "minValue": 3, "maxValue": 25, "defaultValue": 3 }, { "#": "3", "label": "Remember the Last Status", "description": "Remember or not", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Do not remember", "value": 0 }, { "label": "Remember", "value": 1 } ] }, { "#": "4", "label": "Switch 1 Switching Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Single pole double throw", "value": 0 }, { "label": "Toggle switch", "value": 1 } ] } ], "metadata": { "inclusion": "1. Put the Z-Wave Controller into inclusion mode.\n2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode.", "exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.", "reset": "(This procedure should only be used when the primary controller is no longer operational.)\n1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.\n2. Within 1 second of step 1, press link key again and hold until LED is off (about 5 sec.).\n3. Node ID is excluded, and the unit is returned to the factory default state.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2213/AN179_A501112256R.pdf" } }