{ "manufacturer": "Seco", "manufacturerId": "0x0301", "label": "Zwave Clamp", "description": "Clamp Energy Meter", "devices": [ { "productType": "0x0048", "productId": "0x010f" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "2", "label": "MEAS_PERIOD", "valueSize": 1, "unit": "seconds", "minValue": 30, "maxValue": 120, "defaultValue": 30 }, { "#": "3", "label": "MAX_REP_INTERVAL", "valueSize": 1, "minValue": 3, "maxValue": 60, "defaultValue": 6 }, { "#": "4", "label": "RES_ACTIVE_POWER", "valueSize": 1, "unit": "W", "minValue": 1, "maxValue": 100, "defaultValue": 4 }, { "#": "5", "label": "RES_RMS_VOLTAGE", "valueSize": 2, "minValue": 1, "maxValue": 1000, "defaultValue": 10 }, { "#": "6", "label": "RES_RMS_CURRENT", "valueSize": 2, "minValue": 1, "maxValue": 1000, "defaultValue": 10 }, { "#": "8", "label": "CLAMP_REVERSED", "valueSize": 1, "defaultValue": 255, "unsigned": true, "readOnly": true, "allowManualEntry": false, "options": [ { "label": "Clamp placed correctly", "value": 0 }, { "label": "Clamp is reversed", "value": 1 }, { "label": "Could not detect position", "value": 255 } ] }, { "#": "9", "label": "ENABLE_CRC16", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "False", "value": 0 }, { "label": "True", "value": 1 } ] }, { "#": "10", "label": "AVG_PERIOD", "valueSize": 1, "minValue": 0, "maxValue": 6, "defaultValue": 1 } ] }