{ "manufacturer": "LEEDARSON LIGHTING CO., Ltd.", "manufacturerId": "0x0300", "label": "7AA-SS-VE-A0", "description": "Bypass Door Window Sensor Z-Wave 700", "devices": [ { "productType": "0x0301", "productId": "0x0041", "zwaveAllianceId": 4298 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true }, "2": { "label": "On/Off Control", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "label": "Magnetic Field Range", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Parameter 2: 1-19200 µT; Parameter 3: 1-8960 µT", "value": 0 }, { "label": "Parameter 2: 1-192000 µT; Parameter 3: 1-89600 µT", "value": 1 } ] }, { "#": "2", "label": "Average Magnetic Field", "valueSize": 4, "unit": "µT", "minValue": 1, "maxValue": 192000, "defaultValue": 640 }, { "#": "3", "label": "Magnetic Field Offset", "valueSize": 4, "unit": "µT", "minValue": 1, "maxValue": 89600, "defaultValue": 200 }, { "#": "10", "label": "Low Battery Threshold", "valueSize": 1, "unit": "%", "minValue": 5, "maxValue": 50, "defaultValue": 10 }, { "#": "14", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Basic Set Commands" }, { "#": "15", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Invert Sensor State" }, { "#": "20", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Bypass Mode", "defaultValue": 1 }, { "#": "21", "label": "Temperature Reporting Interval", "valueSize": 1, "unit": "minutes", "minValue": 15, "maxValue": 127, "defaultValue": 15 }, { "#": "254", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Lock Configuration" } ], "metadata": { "inclusion": "1. Power on your Door Sensor, set your Z-Wave controller into add/inclusion mode.\n2. Trigger this action\n3. LED will flash green during the inclusion, and then solid green for 2 seconds to indicate the inclusion is successful, otherwise the LED will solid red for 2 seconds in which you need to repeat the process form step 2", "exclusion": "1. Power on your Door Sensor, and let the Z-Wave primary controller into remove/exclusion mode.\n2. Trigger this action.\n3. LED will flash red during the exclusion, and then solid red for 2 seconds to indicate that the exclusion is successful, otherwise the LED will solid green for 2 seconds in which you need to repeat the process form step 2.", "reset": "LED will blink red faster and faster within 5 seconds and then keep solid red until the button is released. Device will reset itself to factory default by sending a “Device Reset Locally Notification” to gateway when the button is released.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4298/zwave700%20DW%20sensor%207AA-SS-VE-A0%20user%20manual-20210910.pdf" } }