{ "manufacturer": "TechniSat", "manufacturerId": "0x0299", "label": "Dimmer Switch", "description": "Flush Dimmer Switch", "devices": [ { "productType": "0x0004", "productId": "0x1a92" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Central Scene Notifications", "description": "Enable/disable central scene notifications for 2x-5x button presses.", "defaultValue": 1 }, { "#": "2", "label": "Report Interval", "description": "Allowable range: 3-8640 (30 seconds to 1 day)", "valueSize": 2, "unit": "10s", "minValue": 0, "maxValue": 8640, "defaultValue": 3, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "3", "label": "Energy Meter Report Interval", "description": "Allowable range: 10-30240 (10 minutes to 3 weeks)", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 30240, "defaultValue": 60, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "4", "label": "Button Operation Mode", "description": "Operations mode for push buttons controlling the output. - Normal Switch: In this mode the top button will turn the output on, while the bottom button will turn the output off. - Toggle Switch: In this mode any button press will toggle the output - when on it will be turned off, when off it will be turned on.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Normal switch", "value": 0 }, { "label": "External push button", "value": 1 } ] }, { "#": "5", "label": "External Switch Type", "description": "Configuration of switch type connected to extension input S. - External Normal Switch: Use this value if a toggle switch is connected to extension input S. - External Push Button: Use this value if a push button switch is connected to extension input S.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "External normal switch", "value": 0 }, { "label": "External push button", "value": 1 } ] }, { "#": "6", "label": "External Switch Mapping", "description": "Central Scene mapping of extension input S.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, /* eslint-disable @zwave-js/consistent-config-string-case */ "options": [ { "label": "Map extension input S. On the Central Scene of T1.", "value": 1 }, { "label": "Map extension input S. On the Central Scene of T2.", "value": 2 }, { "label": "Map extension input S. On a custom Central Scene.", "value": 3 } ] /* eslint-enable @zwave-js/consistent-config-string-case */ } ] }