{ "manufacturer": "Smartly AS", "manufacturerId": "0x024f", "label": "FWC01", "description": "Wheel Controller", "devices": [ { "productType": "0x0003", "productId": "0x1003" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "4", "label": "Safety Activate Delay", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 0 }, { "#": "5", "label": "Safety OFF Period", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 600 }, { "#": "6", "label": "Safety ON Period", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 300 }, { "#": "10", "label": "Dimming Speed", "valueSize": 2, "unit": "0.01s", "minValue": 30, "maxValue": 32767, "defaultValue": 300 }, { "#": "11", "label": "Dimmer Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1, "options": [ { "label": "Leading edge", "value": 0 }, { "label": "Tailing edge", "value": 1 } ] }, { "#": "12", "label": "Maximum Level", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 90 }, { "#": "13", "label": "Minimum Level", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 15 }, { "#": "14[0x01]", "label": "Thermostat Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Disable / Auto", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "14[0x02]", "label": "Light Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Disable / Auto", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "14[0x04]", "label": "Central Scene Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Disable / Auto", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "14[0x30]", "label": "Light Zones", "description": "Select number of Light Zones controllable via the device UI", "valueSize": 1, "minValue": 0, "maxValue": 3, "defaultValue": 0, "unsigned": true, "options": [ { "label": "1 light zone", "value": 0 }, { "label": "2 light zones", "value": 1 }, { "label": "3 light zones", "value": 2 }, { "label": "4 light zones", "value": 3 } ] }, { "#": "15[0x01]", "label": "Light Control Mode", "description": "Enable Switch Mode for ALL zones at once!", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Dimmer mode", "value": 0 }, { "label": "Switch mode", "value": 1 } ] }, { "#": "15[0x02]", "label": "Zone 1 Control Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Dimmer mode", "value": 0 }, { "label": "Switch mode", "value": 1 } ] }, { "#": "15[0x04]", "label": "Zone 2 Control Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Dimmer mode", "value": 0 }, { "label": "Switch mode", "value": 1 } ] }, { "#": "15[0x08]", "label": "Zone 3 Control Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Dimmer mode", "value": 0 }, { "label": "Switch mode", "value": 1 } ] }, { "#": "15[0x10]", "label": "Zone 4 Control Mode", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Dimmer mode", "value": 0 }, { "label": "Switch mode", "value": 1 } ] }, { "#": "17", "label": "Back Unit Role", "valueSize": 1, "minValue": 0, "maxValue": 2, "defaultValue": 1, "options": [ { "label": "Thermostat controlled", "value": 0 }, { "label": "Light zone controlled", "value": 1 }, { "label": "Remote controlled", "value": 2 } ] }, { "#": "18", "label": "Back Unit Light Zone", "valueSize": 1, "minValue": 1, "maxValue": 4, "defaultValue": 1, "options": [ { "label": "Light zone 1", "value": 1 }, { "label": "Light zone 2", "value": 2 }, { "label": "Light zone 3", "value": 3 }, { "label": "Light zone 4", "value": 4 } ] }, { "#": "32", "label": "Thermostat Set Point Max", "valueSize": 2, "unit": "0.1 °C", "minValue": 0, "maxValue": 500, "defaultValue": 270 }, { "#": "34", "label": "Thermostat Set Point Min", "valueSize": 2, "unit": "0.1 °C", "minValue": 0, "maxValue": 500, "defaultValue": 50 }, { "#": "36", "label": "Thermostat Control Resend Interval", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 3600 }, { "#": "37", "label": "Thermostat Minimum On/Off Interval", "valueSize": 2, "unit": "seconds", "minValue": 60, "maxValue": 32767, "defaultValue": 300 }, { "#": "38", "label": "Thermostat Floor Temp Max", "valueSize": 2, "unit": "0.1 °C", "minValue": 0, "maxValue": 500, "defaultValue": 270 }, { "#": "40", "label": "Temperature Sensor Select", "valueSize": 1, "minValue": 1, "maxValue": 3, "defaultValue": 3, "options": [ { "label": "Local room", "value": 1 }, { "label": "Local floor", "value": 2 }, { "label": "Room and floor", "value": 3 } ] }, { "#": "44", "label": "Cold Start Minimum Level", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 20 }, { "#": "64", "label": "Temperature Report Interval", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 600 }, { "#": "66", "label": "Temperature Report Threshold", "valueSize": 1, "unit": "0.1 °C", "minValue": 0, "maxValue": 127, "defaultValue": 10 }, { "#": "67", "label": "Thermostat On/Off Interval Override Threshold", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 0 }, { "#": "240", "label": "Floor Sensor Temperature Offset", "valueSize": 1, "unit": "0.1 °C", "minValue": -128, "maxValue": 127, "defaultValue": 0 }, { "#": "241", "label": "Room Sensor Temperature Offset", "valueSize": 1, "unit": "0.1 °C", "minValue": -128, "maxValue": 127, "defaultValue": 0 } ] }