{ "manufacturer": "TIMEVALVE, Inc.", "manufacturerId": "0x022a", "label": "HY-15-05", "description": "TIMEVALVE SMART", "devices": [ { "productType": "0x0100", "productId": "0x0100", "zwaveAllianceId": 1317 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Valve Default Timeout", "valueSize": 4, "unit": "seconds", "minValue": 300, "maxValue": 2400, "defaultValue": 2400 }, { "#": "3", "label": "Remaining Time to Close", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 35400, "defaultValue": 2400 }, { "#": "100", "label": "Valve Report Interval", "valueSize": 4, "unit": "seconds", "minValue": 600, "maxValue": 16777215, "defaultValue": 86400 } ], "metadata": { "inclusion": "To enter learn mode(inclusion), press UP arrow for 5 seconds while the valve is open", "exclusion": "To enter learn mode(exclusion), press UP arrow for 5 seconds while the valve is open", "reset": "To reset, Press DOWN arrow for 5 seconds while the valve is open.\nPlease use this procedure only in the event that the network primary controller is missing or otherwise inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1317/TIMEVALVE_SMART_MANUAL.pdf" } }