{ "manufacturer": "HANK Electronics Ltd.", "manufacturerId": "0x0208", "label": "HKZW-SO05", "description": "Smart Plug", "devices": [ { "productType": "0x0100", "productId": "0x000a" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "20", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Overload Protection", "description": "Turn off if the load power exceeds 0.5A for more than 5s.", "defaultValue": 1 }, { "#": "21", "$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off" }, { "#": "24", "label": "Load Status Change Notification", "description": "Send notification to associated devices when load is changed.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Function is disabled", "value": 0 }, { "label": "Send Basic Report", "value": 1 }, { "label": "Only when load is not changed", "value": 2 } ] }, { "#": "27", "label": "Indicator Modes", "description": "The RGB LED indicator will indicate the load.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Work in indicator mode", "value": 0 }, { "label": "Indicate for 5 seconds after load has changed", "value": 1 } ] }, { "#": "151", "label": "Power Report Threshold", "description": "Power threshold for when to send reports to associated devices", "valueSize": 2, "unit": "W", "minValue": 0, "maxValue": 65535, "defaultValue": 50, "unsigned": true }, { "#": "152", "label": "Power Report Percentage Threshold", "description": "Percentage threshold for when to send report to associated devices", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true }, { "#": "171", "label": "Power Report Frequence", "description": "The interval of sending power report to association device.", "valueSize": 4, "unit": "seconds", "minValue": 5, "maxValue": 2678400, "defaultValue": 30 }, { "#": "172", "label": "Energy Report Frequence", "description": "The interval of sending energy report to association device.", "valueSize": 4, "unit": "seconds", "minValue": 5, "maxValue": 2678400, "defaultValue": 300 }, { "#": "173", "label": "Voltage Report Frequency", "description": "The interval of sending voltage report to association device.", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 0 }, { "#": "174", "label": "Electricity Report Frequency", "description": "The interval of sending electricity report to association device.", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 0 } ] }