{ "manufacturer": "Heatit", "manufacturerId": "0x019b", "label": "Z-TRM3", "description": "Floor Thermostat", "devices": [ { "productType": "0x0003", "productId": "0x0203" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "2", "label": "Sensor Mode", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "F-Mode, floor sensor mode", "value": 0 }, { "label": "A-Mode, internal room sensor mode", "value": 1 }, { // eslint-disable-next-line @zwave-js/consistent-config-string-case "label": "AF-Mode, internal sensor and floor sensor mode", "value": 2 }, { "label": "A2-mode, external room sensor mode", "value": 3 }, { "label": "A2F-mode, external sensor with floor limitation", "value": 4 } ] }, { "#": "3", "label": "Floor Sensor Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "10K-NTC", "value": 0 }, { "label": "12K-NTC", "value": 1 }, { "label": "15K-NTC", "value": 2 }, { "label": "22K-NTC", "value": 3 }, { "label": "33K-NTC", "value": 4 }, { "label": "47K-NTC", "value": 5 } ] }, { "#": "4", "label": "Temperature Control Hysteresis (DIFF I)", "valueSize": 1, "unit": "0.1 °C", "minValue": 3, "maxValue": 30, "defaultValue": 5 }, { "#": "5", "label": "Floor Minimum Temperature Limit (FLo)", "valueSize": 2, "unit": "0.1 °C", "minValue": 50, "maxValue": 400, "defaultValue": 50 }, { "#": "6", "label": "Floor Maximum Temperature (FHi)", "valueSize": 2, "unit": "0.1 °C", "minValue": 50, "maxValue": 400, "defaultValue": 400 }, { "#": "7", "label": "Air Minimum Temperature Limit (ALo)", "valueSize": 2, "unit": "0.1 °C", "minValue": 50, "maxValue": 400, "defaultValue": 50 }, { "#": "8", "label": "Air Maximum Temperature Limit (AHi)", "valueSize": 2, "unit": "0.1 °C", "minValue": 50, "maxValue": 400, "defaultValue": 400 }, { "#": "10", "label": "Room Sensor Calibration", "valueSize": 1, "unit": "0.1 °C", "minValue": -60, "maxValue": 60, "defaultValue": 0 }, { "#": "11", "label": "Floor Sensor Calibration", "valueSize": 1, "unit": "0.1 °C", "minValue": -60, "maxValue": 60, "defaultValue": 0 }, { "#": "12", "label": "External Sensor Calibration", "valueSize": 1, "unit": "0.1 °C", "minValue": -60, "maxValue": 60, "defaultValue": 0 }, { "#": "13", "label": "Temperature Display", "description": "Selects which temperature is shown on the display.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Display setpoint temperature", "value": 0 }, { "label": "Display calculated temperature", "value": 1 } ] }, { "#": "14", "label": "Button Brightness - Dimmed State", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 50 }, { "#": "15", "label": "Button Brightness - Active State", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "16", "label": "Display Brightness - Dimmed State", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 50 }, { "#": "17", "label": "Display Brightness - Active State", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 100 }, { "#": "18", "label": "Temperature Report Interval", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 60 }, { "#": "19", "label": "Temperature Report Hysteresis", "valueSize": 1, "unit": "°C/10", "minValue": 1, "maxValue": 100, "defaultValue": 10 }, { "#": "20", "label": "Meter Report Interval", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 90 }, { "#": "21", "label": "Meter Report Delta Value", "valueSize": 1, "unit": "kWh/10", "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true } ], "compat": { "commandClasses": { "add": { "Multilevel Sensor": { "endpoints": { "2": { "isSupported": true }, "3": { "isSupported": true }, "4": { "isSupported": true } } } } }, "overrideFloatEncoding": { "size": 2 } } }