{ "manufacturer": "Heatit", "manufacturerId": "0x019b", "label": "Z-Dim", "description": "Knob Smart Dimmer", "devices": [ { "productType": "0x0003", "productId": "0x2200" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Connected Load", "description": "Defines the value of connected load", "valueSize": 1, "minValue": 0, "maxValue": 200, "defaultValue": 0, "unsigned": true }, { "#": "2", "label": "Minimum Dim Level", "description": "Defines the lowest dimming level", "valueSize": 1, "minValue": 1, "maxValue": 98, "defaultValue": 20 }, { "#": "3", "label": "Maximum Dim Level", "description": "Defines the highest dimming level of the dimmer", "valueSize": 1, "minValue": 2, "maxValue": 99, "defaultValue": 85 }, { "#": "4", "label": "Total Steps", "description": "How many steps it should take to dim from min to max", "valueSize": 1, "minValue": 5, "maxValue": 255, "defaultValue": 15, "unsigned": true }, { "#": "5", "label": "Double Press Function", "valueSize": 1, "defaultValue": 0, "readOnly": true, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Dim to highest level", "value": 1 } ] }, { "#": "6", "label": "Scene Controller", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Active", "value": 1 } ] }, { "#": "7", "label": "Switch ON Level", "description": "Defines the dim level when restored from OFF state by push button", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 99, "defaultValue": 0 }, { "#": "8", "label": "Dimming Duration", "description": "Defines how long it takes to dim to desired level.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "9", "label": "Meter Report Interval", "description": "Defines report interval for Power Metering", "valueSize": 2, "minValue": 0, "maxValue": 32767, "defaultValue": 60 }, { "#": "10", "label": "Power Restore Level", "description": "Defines initial dimming level after power loss.", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 99, "defaultValue": 50 } ] }