{ "manufacturer": "Sensative AB", "manufacturerId": "0x019a", "label": "11 04 021/022/028", "description": "Strips Drip 700", "devices": [ { "productType": "0x0004", "productId": "0x000b", "zwaveAllianceId": [4075, 4154, 4159, 4301, 4442, 4448] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "2", "$import": "~/templates/master_template.json#enable_led_indicator", "defaultValue": 1 }, { "#": "4", "label": "Temperature Reporting", "valueSize": 1, "minValue": 0, "maxValue": 3, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable - Change threshold reporting", "value": 1 }, { "label": "Enable - Timed reporting of actual values", "value": 2 }, { "label": "Enable - Timed reporting of average values", "value": 3 } ] }, { "#": "5", "$import": "~/templates/master_template.json#temperature_scale_celsius_fahrenheit" }, { "#": "6", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Temperature Alarms" }, { "#": "7", "label": "High Temperature Threshold", "valueSize": 1, "unit": "°C", "minValue": -20, "maxValue": 80, "defaultValue": 40 }, { "#": "8", "label": "Low Temperature Threshold", "valueSize": 1, "unit": "°C", "minValue": -20, "maxValue": 60, "defaultValue": 5 }, { "#": "26", "label": "Temperature Reporting Threshold", "valueSize": 1, "unit": "0.1 °C", "minValue": 5, "maxValue": 100, "defaultValue": 20 }, { "#": "27", "label": "Temperature Recover Limit", "valueSize": 1, "unit": "0.1 °C", "minValue": 5, "maxValue": 100, "defaultValue": 20 }, { "#": "12", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Moisture Alarm", "defaultValue": 1 }, { "#": "13", "label": "Moisture Alarm Threshold", "description": "Higher value means greater amount of wetness detected", "valueSize": 1, "minValue": 1, "maxValue": 100, "defaultValue": 10 }, { "#": "14", "label": "Moisture Alarm Reporting Interval", "valueSize": 1, "unit": "hours", "minValue": 0, "maxValue": 120, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "20", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Moisture Reporting During Wakeups" }, { "#": "15", "label": "Supervision Commands", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Alarm reports only", "value": 1 }, { "label": "All reports", "value": 2 } ] }, { "#": "23", "label": "Moisture Sensor Calibration", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "options": [ { "label": "Normal operation", "value": 0 }, { "label": "Begin calibration", "value": 1 } ] }, { "#": "24", "label": "Temperature Offset Value", "valueSize": 1, "unit": "0.1 °C", "minValue": -100, "maxValue": 100, "defaultValue": 0 }, { "#": "25", "label": "Temperature Reporting Interval", "valueSize": 2, "unit": "minutes", "minValue": 15, "maxValue": 1440, "defaultValue": 1440 } ], "metadata": { "inclusion": "Place the controller into inclusion mode and perform the \"wake up\" pattern as described below.\n1. Take the magnet and move it to the rounded edge and wait for the blink, then move the magnet away.\n2. Repeat this 3 times. A final short blink will confirm that the inclusion was successful", "exclusion": "Place the controller into exclusion mode and perform the \"wake up\" pattern as described below.\n1. Take the magnet and move it to the rounded edge and wait for the blink, then move the magnet away.\n2. Repeat this 3 times. A final short blink will confirm that the exclusion was successful", "reset": "Follow the instructions for Wake Up above, but on the 3rd repetition, keep the magnet at the rounded edge for 10 seconds. A long LED signal indicates success", "wakeup": "Place a magnet at the rounded edge. When the LED blinks, move the magnet away. Repeat a total of 3 times within 10 seconds, A LED blink indicates success.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4301/Strips%20Drip%20700%20manual.pdf" } }