{ "manufacturer": "Climax Technology, Ltd.", "manufacturerId": "0x018e", "label": "RMB-35ZW", "description": "Z-Wave Router / USB Power Adaptor", "devices": [ { "productType": "0x0004", "productId": "0x000f", "zwaveAllianceId": 3787 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "metadata": { "inclusion": "1. Connect the Router into the power socket to power on. \n2. Put the Z-Wave Gateway or Control Panel into Inclusion mode (please refer to the Z-Wave Gateway or Control Panel manual).\n3. Within 1.5 seconds, press the Function Button 3 times.\n4. Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete the adding process.\n5. If the sensor has already been added (included) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be added into the current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel.", "exclusion": "1. Put the Z-Wave Gateway or Control Panel into Exclusion mode (please refer to the Z-Wave Gateway or Control Panel manual).\n2. Within 1.5 seconds, press the Function Button 3 times and the Router will be removed from the Z-Wave network.", "reset": "(Only use factory reset when network Control Panel/Gateway is missing or inoperable).\nPress and hold the Function Button for 10 seconds to factory reset", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3787/RMB-35-ZW_2A_20200122.pdf" } }