{ "manufacturer": "Devolo", "manufacturerId": "0x0175", "label": "MT2761", "description": "Home Control Shutter", "devices": [ { "productType": "0x0003", "productId": "0x0052", "zwaveAllianceId": 2962 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true, // The device does not like Endpoint Associations for the lifeline "multiChannel": false }, "2": { "label": "Basic on/off - triggered at change of the input I1 state and reflecting its state.", "maxNodes": 16 }, "3": { "label": "Basic on/off - triggered at change of the input I2 state and reflecting its state.", "maxNodes": 16 }, "4": { "label": "Basic on/off - triggered at sensing moving direction of roller: up=FF, down=0.", "maxNodes": 16 }, "5": { "label": "Basic on/off - triggered at reaching roller position: bottom=FF, top=0.", "maxNodes": 16 }, "6": { "label": "Basic on/off - triggered at reaching roller position: bottom=FF, not bottom=0.", "maxNodes": 16 }, "7": { "label": "Multilevel set - triggered at changes of value of the Flush Shutter DC position.", "maxNodes": 16 }, "8": { "label": "Multilevel set - triggered at changes of value of slats tilting position.", "maxNodes": 16 }, "9": { "label": "Multilevel sensor report - triggered at change of temperature sensor.", "maxNodes": 16, "isLifeline": true, // The device does not like Endpoint Associations for the lifeline "multiChannel": false } }, "paramInformation": [ { "#": "10", "label": "ALL ON/ALL OFF", "description": "Responds to commands ALL ON / ALL OFF from Main Controller", "valueSize": 2, "defaultValue": 255, "allowManualEntry": false, "options": [ { "label": "All on is not active all off is not active", "value": 0 }, { "label": "All on is not active all off active", "value": 1 }, { "label": "All on is not active all off is not active", "value": 2 }, { "label": "All on active, all off active", "value": 255 } ] }, { "#": "40", "label": "Power Reporting in Watts on Power Change", "description": "Power consumption change threshold for sending updates", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 1 }, { "#": "42", "label": "Power Reporting in Watts by Time Interval", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 300 }, { "#": "71", "label": "Operating Modes", "description": "Operation Mode (Shutter or Venetian)", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Shutter mode", "value": 0 }, { "label": "Venetian mode (Up/Down and slate rotation)", "value": 1 } ] }, { "#": "72", "label": "Slats Tilting Full Turn Time", "description": "Slat full turn time in tenths of a second.", "valueSize": 2, "unit": "tenths of a seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 150 }, { "#": "73", "label": "Slats Position", "description": "Slats position after up/down movement.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Previous position for Z-Wave control only", "value": 0 }, { "label": "Return to previous position in all cases", "value": 1 } ] }, { "#": "74", "label": "Motor Moving Up/down Time", "description": "Shutter motor moving time of complete opening or complete closing", "valueSize": 2, "minValue": 0, "maxValue": 32767, "defaultValue": 0 }, { "#": "76", "label": "Motor Operation Detection", "description": "Power threshold to be interpreted when motor reach the limit switch", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 10 }, { "#": "78", "label": "Forced Shutter Calibration", "description": "Enters calibration mode if set to 1", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Default", "value": 0 }, { "label": "Start calibration process", "value": 1 } ] }, { "#": "80", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Reporting to Controller", "description": "Defines if reporting regarding power level, etc is reported to controller.", "defaultValue": 1 }, { "#": "85", "label": "Power Consumption Max Delay Time", "description": "Time delay for detecting motor errors", "valueSize": 1, "minValue": 0, "maxValue": 50, "defaultValue": 8 }, { "#": "86", "label": "Power Consumption At Limit Switch Delay Time", "description": "Sets the time delay for detecting limit switches", "valueSize": 1, "minValue": 3, "maxValue": 50, "defaultValue": 8 }, { "#": "90", "label": "Relay Delay Time", "description": "Defines the minimum time delay between next motor movement", "valueSize": 1, "unit": "ms", "minValue": 1, "maxValue": 30, "defaultValue": 5 }, { "#": "110", "label": "Temperature Sensor Offset Settings", "description": "Adds or removes an offset from the measured temperature.", "valueSize": 2, "minValue": 1, "maxValue": 32536, "defaultValue": 32536 }, { "#": "120", "label": "Digital Temperature Sensor Reporting", "description": "Threshold for sending temperature change reports", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 5 } ], "metadata": { "inclusion": "Module Inclusion (Adding to Z-wave network)\n• Connect module to power supply (with \ntemperature sensor connected - if purchased),\n• auto-inclusion (works for about 5 seconds after connected to power supply) or\n• press push button I1 three times within 3s (3 times change switch state within 3 seconds) or\n• press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.\nNOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.\nNOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.", "exclusion": "Module Exclusion (Removing from Z-Wave network)\n• Connect module to power supply \n• bring module within maximum 1 meter (3 feet) of the main controller,\n• enable add/remove mode on main controller\nIf push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to their default values.", "reset": "• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or\n• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.\nBy this function all parameters of the module are set to their default values and the ID of the device is deleted.\nNOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.\nNOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2962/Manual_Devolo_HC%20Shutter_FM.pdf" } }