{ "manufacturer": "Devolo", "manufacturerId": "0x0175", "label": "MT02792", "description": "Home Control Metering Plug", "devices": [ { "productType": "0x0001", "productId": "0x0012" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Watt Counter Reporting Period", "description": "multiples of 5s", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 720, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "2", "label": "KWh Counter Reporting Period", "description": "number of 10 minute intervals", "valueSize": 2, "unit": "10m", "minValue": 0, "maxValue": 32767, "defaultValue": 6, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "3", "label": "Definition of Warning of Current Load (A)", "description": "1300*0.01A = 13A", "valueSize": 2, "unit": "0.01A", "minValue": 10, "maxValue": 1300, "defaultValue": 1300 }, { "#": "4", "label": "Load Caution Threshold", "valueSize": 2, "minValue": 1, "maxValue": 10000, "defaultValue": 10000 }, { "#": "5", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on" }, { "#": "6", "label": "Switch OFF Mode", "description": "Mode of switch off function.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Switch off commands received are ignored", "value": 0 }, { "label": "Switch off commands received are honored", "value": 1 } ] }, { "#": "7", "label": "LED Display Mode", "description": "Display device status", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "The LED follows the state of the switch", "value": 1 }, { "label": "LED off with load on", "value": 2 }, { "label": "Flash mode", "value": 3 } ] }, { "#": "8", "label": "Auto Off Timer", "description": "Auto off timer. 0 will disable the auto off function.", "valueSize": 2, "unit": "1s", "minValue": 0, "maxValue": 32767, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "9", "label": "Device From Command Status", "description": "RF off command mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "When all off is received, MT2792 goes off", "value": 0 }, { "label": "Ignore all off", "value": 1 }, { "label": "If all off is received, turn on if it is off", "value": 2 }, { "label": "WhenALL off is received, the MT2792 goes on", "value": 3 } ] } ] }