{ "manufacturer": "Fantem", "manufacturerId": "0x016a", "label": "FT132", "description": "Dual Nano Switch with Energy Metering", "devices": [ { "productType": "0x0003", "productId": "0x008c" }, { "productType": "0x0203", "productId": "0x0084" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "3", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Current Overload Protection", "defaultValue": 1 }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Overheat Protection" }, { "#": "20", "$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off" }, { "#": "80", "label": "Group 1 Notifications", "description": "To set which notification would be sent to the associated devices (Group 1)", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send nothing", "value": 0 }, { "label": "Send Hail CC", "value": 1 }, { "label": "Send Basic CC Report", "value": 2 }, { "label": "Send Hail CC when using the manual switch", "value": 3 } ] }, { "#": "81", "label": "Group 3 Notifications", "description": "To set which notification would be sent to association group 3", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Send nothing", "value": 0 }, { "label": "Send Basic Set cc", "value": 1 } ] }, { "#": "82", "label": "Group 4 Notifications", "description": "To set which notification would be sent to association group 4", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Send nothing", "value": 0 }, { "label": "Send Basic CC Set", "value": 1 } ] }, { "#": "90", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Enable/disable Parameters 91 and 92" }, { "#": "91", "label": "Set the Threshold Value of Wattage", "valueSize": 2, "minValue": 0, "maxValue": 60000, "defaultValue": 25, "unsigned": true }, { "#": "92", "label": "Set the Threshold Value of Percent Power", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 5 }, { "#": "100", "label": "Set Parameter 101-103 to Default Value", "description": "Reset the parameter 101-103", "valueSize": 1, "minValue": 0, "maxValue": 0, "defaultValue": 0, "writeOnly": true }, { "#": "101", "label": "Set Group 1 Reports", "description": "To set which reports need to be sent in Report group 1", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send Meter Report of energy (kWh)", "value": 1 }, { "label": "Send Meter Report of wattage (W)", "value": 2 }, { "label": "Send Meter Report of voltage (V)", "value": 4 }, { "label": "Send Meter Report of current (A)", "value": 8 }, { "label": "Meter Report of wattage (W) on channel 1", "value": 256 }, { "label": "Meter Report of wattage (W) on channel 2", "value": 512 }, { "label": "Meter Report of energy (kWh) on channel 1", "value": 2048 }, { "label": "Meter Report of energy (kWh) on channel 2", "value": 4096 }, { "label": "Meter Report of voltage (V) on channel 1", "value": 65536 }, { "label": "Meter Report of voltage (V) on channel 2", "value": 131072 }, { "label": "Meter Report of current (A) on channel 1", "value": 524288 }, { "label": "Meter Report of current (A) on channel 2", "value": 1048576 } ] }, { "#": "102", "label": "Reports Sent to Report Group 2", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send Meter Report of energy (kWh)", "value": 1 }, { "label": "Send Meter Report of wattage (W)", "value": 2 }, { "label": "Send Meter Report of voltage (V)", "value": 4 }, { "label": "Send Meter Report of current (A)", "value": 8 }, { "label": "Meter Report of wattage (W) on channel 1", "value": 256 }, { "label": "Meter Report of wattage (W) on channel 2", "value": 512 }, { "label": "Meter Report of energy (kWh) on channel 1", "value": 2048 }, { "label": "Meter Report of energy (kWh) on channel 2", "value": 4096 }, { "label": "Meter Report of voltage (V) on channel 1", "value": 65536 }, { "label": "Meter Report of voltage (V) on channel 2", "value": 131072 }, { "label": "Meter Report of current (A) on channel 1", "value": 524288 }, { "label": "Meter Report of current (A) on channel 2", "value": 1048576 } ] }, { "#": "103", "label": "Reports Sent to Report Group 3", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send Meter Report of voltage (V)", "value": 1 }, { "label": "Send Meter Report of current (A)", "value": 2 }, { "label": "Send Meter Report of wattage (W)", "value": 4 }, { "label": "Send Meter Report of energy (kWh)", "value": 8 }, { "label": "Meter Report of wattage (W) on channel 1", "value": 256 }, { "label": "Meter Report of wattage (W) on channel 2", "value": 512 }, { "label": "Meter Report of energy (kWh) on channel 1", "value": 2048 }, { "label": "Meter Report of energy (kWh) on channel 2", "value": 4096 }, { "label": "Meter Report of voltage (V) on channel 1", "value": 65536 }, { "label": "Meter Report of voltage (V) on channel 2", "value": 131072 }, { "label": "Meter Report of current (A) on channel 1", "value": 524288 }, { "label": "Meter Report of current (A) on channel 2", "value": 1048576 } ] }, { "#": "110", "label": "Set Parameter 111-113 to Default Value", "valueSize": 1, "minValue": 0, "maxValue": 0, "defaultValue": 0, "writeOnly": true }, { "#": "111", "label": "Automatic Report Interval for Report Group 1", "valueSize": 4, "minValue": 1, "maxValue": 2147483647, "defaultValue": 10 }, { "#": "112", "label": "Automatic Report Interval for Report Group 2", "valueSize": 4, "minValue": 1, "maxValue": 2147483647, "defaultValue": 600 }, { "#": "113", "label": "Automatic Report Interval for Report Group 3", "valueSize": 4, "minValue": 1, "maxValue": 2147483647, "defaultValue": 600 }, { "#": "120", "label": "Configure the External Switch Mode for S1", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Enter automatic identification mode", "value": 0 }, { "label": "2-State switch mode", "value": 1 }, { "label": "3 way switch mode", "value": 2 }, { "label": "Momentary push button mode", "value": 3 } ] }, { "#": "121", "label": "Configure the External Switch Mode for S2", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Enter automatic identification mode", "value": 0 }, { "label": "2-State switch mode", "value": 1 }, { "label": "3 way switch mode", "value": 2 }, { "label": "Momentary push button mode", "value": 3 } ] }, { "#": "122", "label": "Set the Control Destination for External Switch", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Control the output loads of itself", "value": 1 }, { "label": "Control the other nodes", "value": 2 }, { "label": "Control the output of itself and others", "value": 3 } ] }, { "#": "252", "label": "Lock/unlock Configuration Parameters", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Unlock", "value": 0 }, { "label": "Lock", "value": 1 } ] }, { "#": "255", "label": "Reset the Dual Nano Switch", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Reset all configuration parameters", "value": 0 }, { "label": "Reset & remove from network", "value": 1431655765 } ] } ] }