{ "manufacturer": "Fantem", "manufacturerId": "0x016a", "label": "FT116", "description": "In-Wall Smart Switch", "devices": [ { "productType": "0x0003", "productId": "0x0074" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "3", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Current Overload Protection", "defaultValue": 1 }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Overheat Protection" }, { "#": "9", "label": "Instant Energy Autosend Interval", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "20", "label": "Output Status After Re-Power", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Last status", "value": 0 }, { "label": "Always on", "value": 1 }, { "label": "Always off", "value": 2 } ] }, { "#": "80", "label": "Group 1 Notifications", "description": "Group 1 notifications when the state of Nano Switch's load is changed", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Send nothing", "value": 0 }, { "label": "Send Hail CC", "value": 1 }, { "label": "Send Basic CC", "value": 2 }, { "label": "Send Hail CC (External switch)", "value": 3 } ] }, { "#": "81", "label": "Group 3 Notifications", "description": "Notification to sent for Group 3 when using the external switch 1", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Send nothing", "value": 0 }, { "label": "Send Basic CC Set", "value": 1 } ] }, { "#": "82", "label": "Group 4 Notifications", "description": "Notification to sent for Group 4 when using the external switch 2", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Send nothing", "value": 0 }, { "label": "Send Basic CC Set", "value": 1 } ] }, { "#": "83", "label": "Configure the State of LED", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "LED follows switch status", "value": 0 }, { "label": "Momentary indicate mode", "value": 1 }, { "label": "Night light mode. The LED will remain on state", "value": 2 } ] }, { "#": "84", "label": "Night Light Mode LED State", "description": "Set the ON/OFF time of the LED when it is in Night light mode", "valueSize": 4, "minValue": 0, "maxValue": 0, "defaultValue": 301991936 }, { "#": "86", "label": "Set Appointment 1", "description": "Set the ON time of output load.", "valueSize": 4, "minValue": 0, "maxValue": 0, "defaultValue": 8327680 }, { "#": "87", "label": "Set Appointment 2", "description": "Set the OFF time of output load", "valueSize": 4, "minValue": 0, "maxValue": 8327680, "defaultValue": 8327680 }, { "#": "90", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Enables/disable Parameter 91 and 92" }, { "#": "91", "label": "Set the Threshold Value of Wattage", "description": "Threshold change in wattage (in terms of wattage) to induce an automatic report", "valueSize": 2, "minValue": 0, "maxValue": 60000, "defaultValue": 25, "unsigned": true }, { "#": "92", "label": "Set the Threshold Value of Percent Power", "description": "Threshold percentage change in wattage for an automatic report", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 5 }, { "#": "100", "label": "Set Parameter 101-103 to Default Value", "description": "Reset the parameter 101-103", "valueSize": 1, "minValue": 0, "maxValue": 0, "defaultValue": 0, "writeOnly": true }, { "#": "101", "label": "Set Group 1 Reports", "description": "To set which reports need to be sent in Report group 1.", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send Meter Report of energy (kWh)", "value": 1 }, { "label": "Send Meter Report of wattage (W)", "value": 2 }, { "label": "Send Meter Report of voltage (V)", "value": 4 }, { "label": "Send Meter Report of current (A)", "value": 8 } ] }, { "#": "102", "label": "Set Group 2 Reports", "description": "To set which reports need to be sent in Report group 2.", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send Meter Report of energy (kWh)", "value": 1 }, { "label": "Send Meter Report of wattage (W)", "value": 2 }, { "label": "Send Meter Report of voltage (V)", "value": 4 }, { "label": "Send Meter Report of current (A)", "value": 8 } ] }, { "#": "103", "label": "Set Group 3 Reports", "description": "To set which reports need to be sent in Report group 3.", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send Meter Report of voltage (V)", "value": 1 }, { "label": "Send Meter Report of current (A)", "value": 2 }, { "label": "Send Meter Report of wattage (W)", "value": 4 }, { "label": "Send Meter Report of energy (kWh)", "value": 8 } ] }, { "#": "110", "label": "Reset the Parameter 111-113", "description": "Set parameter 111-113 to default value.", "valueSize": 1, "minValue": 0, "maxValue": 0, "defaultValue": 0 }, { "#": "111", "label": "Interval for Automatic Report Group 1", "valueSize": 4, "minValue": 1, "maxValue": 2147483647, "defaultValue": 600 }, { "#": "112", "label": "Interval for Automatic Report Group 2", "valueSize": 4, "minValue": 1, "maxValue": 2147483647, "defaultValue": 600 }, { "#": "113", "label": "Interval for Automatic Group 3 Report", "description": "Set the interval of automatic report for Report group 3", "valueSize": 4, "minValue": 1, "maxValue": 2147483647, "defaultValue": 600 }, { "#": "120", "label": "External Switch Mode for S1", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Enter automatic identification mode", "value": 0 }, { "label": "2-State switch mode", "value": 1 }, { "label": "3 way switch mode", "value": 2 }, { "label": "Momentary push button mode", "value": 3 } ] }, { "#": "121", "label": "External Switch Mode for S2", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Enter automatic identification mode", "value": 0 }, { "label": "2-State switch mode", "value": 1 }, { "label": "3 way switch mode", "value": 2 }, { "label": "Momentary push button mode", "value": 3 } ] }, { "#": "122", "label": "Control Destination of External Switch", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Control the output loads of itself", "value": 1 }, { "label": "Control the other nodes", "value": 2 }, { "label": "Control the output loads of itself and other nodes", "value": 3 } ] }, { "#": "252", "label": "Lock/unlock Configuration Parameters", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Unlock", "value": 0 }, { "label": "Lock", "value": 1 } ] }, { "#": "255", "label": "Reset the Nano Switch", "valueSize": 4, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Reset all configuration parameters", "value": 0 }, { "label": "Reset and remove from network", "value": 1431655765 } ] } ] }