{ "manufacturer": "McoHome Technology Co., Ltd.", "manufacturerId": "0x015f", "label": "MH10-PM2.5-WA/WD", "description": "PM2.5 Monitor (Zwave Plus)", "devices": [ { "productType": "0x0a01", "productId": "0x5102" }, { "productType": "0x0a02", "productId": "0x5102" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "2", "label": "PM2.5 Report Interval", "description": "=0 report disabled, ≥10 report when change ≥n*0.1μg/m³", "valueSize": 1, "unit": "0.1μg/m³", "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true, "options": [ { "label": "Report disabled", "value": 0 }, { "label": "Report every whole 1μg/m³ change", "value": 10 } ] }, { "#": "3", "label": "Temperature Report Interval", "description": "=0 report disabled, ≥10 report when change ≥n*0.1μg/m³", "valueSize": 1, "unit": "0.5 °C", "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true, "options": [ { "label": "Report disabled", "value": 0 }, { "label": "Report if changed 0.5℃", "value": 1 } ] }, { "#": "4", "label": "Humidity Report Interval", "description": "=0 report disabled, ≥10 report when change ≥n*0.1μg/m³", "valueSize": 1, "unit": "2%", "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "255", "label": "Factory Setting", "description": "85 (0x55) to restore factory setting", "valueSize": 1, "defaultValue": 0, "writeOnly": true, "allowManualEntry": false, "options": [ { "label": "Normal operation", "value": 0 }, { "label": "Reset to factory settings", "value": 85 } ] } ], "compat": { // The device reports in a different scale than it reports support for "disableStrictMeasurementValidation": true } }