{ "manufacturer": "McoHome Technology Co., Ltd.", "manufacturerId": "0x015f", "label": "MH-S312", "description": "Two Way Switch", "devices": [ { "productType": "0x3102", "productId": "0x0202" }, { "productType": "0x3121", "productId": "0x1302" }, { "productType": "0x3121", "productId": "0x5102" }, { "productType": "0x3122", "productId": "0x5102" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "All Status Reports", "maxNodes": 1, "isLifeline": true }, "2": { "label": "Switch Button Group 1", "maxNodes": 5 }, "5": { "label": "Switch Button Group 2", "maxNodes": 5 } }, "paramInformation": [ { "#": "2", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "3", "label": "ALL ON/ALL OFF", "description": "0,1,2,255", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "4", "label": "LED Backlit Brightness Level", "description": "0=LED disabled 1-10=Min level-Max level", "valueSize": 1, "minValue": 0, "maxValue": 10, "defaultValue": 10 }, { "#": "5", "label": "Key Mode", "description": "0-4", "valueSize": 1, "minValue": 0, "maxValue": 4, "defaultValue": 0 }, { "#": "6", "label": "Key On Duration", "description": "0=infinite 1~65535=unit \"sec\"", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "255", "label": "Factory Setting", "valueSize": 1, "minValue": 85, "maxValue": 85, "defaultValue": 85, "writeOnly": true } ] }