{ "manufacturer": "McoHome Technology Co., Ltd.", "manufacturerId": "0x015f", "label": "MH-P220", "description": "Micro Dimmer", "devices": [ { "productType": "0x220a", "productId": "0x1352" }, { "productType": "0x220a", "productId": "0x5101", "zwaveAllianceId": 3011 }, { "productType": "0x220a", "productId": "0x5102" }, { "productType": "0x220a", "productId": "0x5103" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "2", "label": "External Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Momentary", "value": 0 }, { "label": "Switch", "value": 1 }, { "label": "Roller blind switch - S1 -> up; S2 -> down", "value": 2 } ] }, { "#": "3", "label": "Switch States", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Toggle", "value": 0 }, { "label": "On/Off switch", "value": 1 } ] }, { "#": "4", "label": "All On / All Off", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable all off; Disable all on", "value": 1 }, { "label": "Enable all on; Disable all off", "value": 2 }, { "label": "Enable", "value": 255 } ] }, { "#": "5", "label": "Minimum Brightness", "valueSize": 1, "minValue": 1, "maxValue": 98, "defaultValue": 1 }, { "#": "6", "label": "Maximum Brightness", "valueSize": 1, "minValue": 2, "maxValue": 99, "defaultValue": 99 }, { "#": "7", "label": "Dimming Step Time (Manual)", "valueSize": 2, "unit": "10ms", "minValue": 1, "maxValue": 255, "defaultValue": 3 }, { "#": "8", "label": "Dimming Step Size (Manual)", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "9", "label": "Dimming Step Time (Auto)", "valueSize": 2, "unit": "10ms", "minValue": 1, "maxValue": 255, "defaultValue": 3 }, { "#": "10", "label": "Dimming Step Size (Auto)", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "11", "label": "Auto-Off Timer", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "13", "label": "One Click of S1", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 99 }, { "#": "14", "label": "Double Click of S1", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Max brightness", "value": 1 } ] }, { "#": "15", "label": "Operation Report Switch1 to Association Groups 2 & 3", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "16", "label": "Operation Report Switch1 to Association Group 2", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "On = 0xff", "value": 0 }, { "label": "On = current dimmer value", "value": 1 } ] }, { "#": "17", "label": "Switch 2 Function", "valueSize": 1, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Wire with roller blinds switch", "value": 0 }, { "label": "Scene Activation; Control association group 4", "value": 1 }, { "label": "Scene Activation", "value": 2 }, { "label": "Send Basic CC Set", "value": 3 }, { "label": "Disable", "value": 255 } ] }, { "#": "18", "label": "Association Group 4 Commands", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Basic CC Set (On/Off)", "value": 0 }, { "label": "Basic CC Set (On)", "value": 1 }, { "label": "Basic CC Set (Off)", "value": 2 }, { "label": "Disable", "value": 255 } ] }, { "#": "19", "label": "Scene ID - One Click of S2 (Association Group 1)", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "20", "label": "Scene ID - Double Click of S2 (Association Group 1)", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "21", "label": "Scene ID - Hold of S2 (Association Group 1)", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "255", "label": "Factory Reset", "valueSize": 1, "defaultValue": 0, "writeOnly": true, "allowManualEntry": false, "options": [ { "label": "Normal operation", "value": 0 }, { "label": "Factory reset", "value": 85 } ] } ], "metadata": { "inclusion": "Add the device into Z-Wave network:\n1. Set controller into ADD mode. Follow the instructions provided by the controller/gateway manufacturer.\n2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession. \nNote: If the ADD is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switch’s state.", "exclusion": "Remove the device from Z-Wave network:\n1. Set controller into REMOVE mode. Follow the instructions provided by the controller/gateway manufacturer.\n2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession. \nNote: If the REMOVE is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switch’s state.", "reset": "Restoring Factory Settings:\nThe default configuration can be restored by:\n Sending commands through controller/gateway (the command classes which support this function is Configuration Command Class). The parameter are as follows:\n\nParameter Number 0xFF\nSize 1 BYTE\nDefault value N/A\nConfiguration value 0x55\nSet 0xFF as 0x55 will restore Factory Settings.\n\n Or press the inner button on the module 10 times in quick succession.Please use this procedure only when the network primary controller is missing or otherwise inoperable.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3011/MH-P220UserManual.pdf" } }