{ "manufacturer": "Willis Electric Co., Ltd.", "manufacturerId": "0x015d", "label": "NZW39", "description": "Dimming Plug", "devices": [ { "productType": "0x2700", "productId": "0x2700" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Dimming Step", "description": "Percentage of step when switch is dimming up or down (0 = instant)", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 0 }, { "#": "2", "label": "Minimum Level", "description": "Minimum dimming level for attached light", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "3", "label": "LED Indicator", "description": "Turn LED indicator ON when light is ON (paddle switch only)", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Off", "value": 0 }, { "label": "On", "value": 1 }, { "label": "Disabled", "value": 2 }, { "label": "Always on", "value": 3 } ] }, { "#": "4", "label": "Invert Switch", "description": "Invert on & off on the physical switch", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "5", "label": "Auto OFF", "description": "Automatically turn switch off after this number of seconds", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 0 }, { "#": "7", "label": "Association Group 3 Setting", "description": "Change how devices respond when associated in group 3", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Dim up/down", "value": 0 }, { "label": "Keep in sync", "value": 1 } ] }, { "#": "8", "label": "Default Level (Local)", "description": "Default level when light is turned on at the switch (0 = previous level)", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 0 }, { "#": "9", "label": "Default Level (Z-Wave)", "description": "Default level when light is turned on via Z-Wave command (0 = previous level)", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 0 }, { "#": "6[0x01]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Command On Local Action", "description": "When should the switch send commands to Group 3 devices?", "defaultValue": 1 }, { "#": "6[0x02]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Command On 3-Way Action", "description": "When should the switch send commands to Group 3 devices?" }, { "#": "6[0x04]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Command On Z-Wave Action", "description": "When should the switch send commands to Group 3 devices?" }, { "#": "6[0x08]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Command On Auto Off Timer", "description": "When should the switch send commands to Group 3 devices?" } ] }