{ "manufacturer": "Philio Technology Corp", "manufacturerId": "0x013c", "label": "PSP05", "description": "Motion Sensor", "devices": [ { "productType": "0x0002", "productId": "0x0050" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "2", "label": "Basic Set Level", "description": "Setting the BASIC command value to turn on the light.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "3", "label": "PIR Sensitivity", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 80 }, { "#": "6", "label": "Multi-Sensor Function Switch", "description": "Parameter to set the sensor functions.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "8", "label": "Re-Detection Interval", "description": "Multiples of 8 seconds to wait before re-detection", "valueSize": 1, "minValue": 1, "maxValue": 127, "defaultValue": 3 }, { "#": "9", "label": "Turn Off Light Time", "description": "Time to wait after lighting has been turned on before turning off again", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 4 }, { "#": "10", "label": "Battery Level Reporting Interval", "description": "How frequently battery status should be reported", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 12 }, { "#": "20", "label": "Tick Interval", "description": "Interval time for sending reports", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 30, "unsigned": true }, { "#": "7[0x02]", "label": "Bit 1: Motion OFF Reporting", "description": "Sends notification when motion has completed.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Don't send report", "value": 0 }, { "label": "Send report", "value": 1 } ] }, { "#": "7[0x04]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "PIR Super Sensitivity Mode", "defaultValue": 1 }, { "#": "7[0x10]", "label": "Bit 4: Notification Type", "description": "Method used to send notifications on motion", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Notification Report", "value": 0 }, { "label": "Binary Sensor", "value": 1 } ] }, { "#": "7[0x20]", "$import": "~/templates/master_template.json#base_enable_disable_inverted", "label": "Send Multi CC in Auto Report", "defaultValue": 0 }, { "#": "7[0x40]", "$import": "~/templates/master_template.json#base_enable_disable_inverted", "label": "Send Battery Report When Triggered", "description": "Whether or not a battery status report should be sent when triggered", "defaultValue": 0 } ] }