{ "manufacturer": "Philio Technology Corp", "manufacturerId": "0x013c", "label": "PAT02-C", "description": "Flood Sensor", "devices": [ { "productType": "0x0002", "productId": "0x0021" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Basic Set OFF Level", "description": "Setting the BASIC command value", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "2", "label": "Basic Set ON Level", "description": "Setting the BASIC command value", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "5", "label": "Operation Mode", "description": "Operation mode. Using bit to control.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Flood function is enabled", "value": 32 }, { "label": "Flood function is disabled", "value": 33 } ] }, { "#": "7", "label": "Customer Function", "description": "Parameter to set the sensor functions", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "10", "label": "Auto Report Battery Time", "description": "The interval time for auto report the battery level.", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 12 }, { "#": "15", "label": "Auto Report Flood Time", "description": "The interval time for auto report the flood state.", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 12 }, { "#": "20", "label": "Auto Report Tick Interval", "description": "The interval time for auto reporting each tick.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 30, "unsigned": true } ] }