{ "manufacturer": "Philio Technology Corp", "manufacturerId": "0x013c", "label": "PAN34", "description": "In Wall Roller Shutter Controller", "devices": [ { "productType": "0x0001", "productId": "0x0080", "zwaveAllianceId": [4250, 4267, 4269, 4270, 4274, 4275, 4283, 4284, 4290, 4291] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Power Reporting Interval", "valueSize": 2, "unit": "5 seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 720, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "2", "label": "External Switch Mode", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "One button", "value": 1 }, { "label": "Two buttons", "value": 2 } ] }, { "#": "3", "label": "Curtain Moving Time", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 6000, "defaultValue": 0, "options": [ { "label": "Per calibration", "value": 0 } ] }, { "#": "4", "label": "Power Threshold for Motor Movement", "valueSize": 1, "unit": "W", "minValue": 1, "maxValue": 5, "defaultValue": 1 }, { "#": "5", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Meter Reports", "description": "Triggered by a greater than 5% power variation", "defaultValue": 1 }, { "#": "6", "label": "Timer Offset for Motor Start", "valueSize": 2, "unit": ".01 seconds", "minValue": 0, "maxValue": 255, "defaultValue": 50 } ], "metadata": { "inclusion": "1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. \n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode", "exclusion": "1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. \n2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode. \n3. Node ID has been excluded", "reset": "1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. \n2. Within 1 second, press On/Off button again for 5 seconds. \n3. IDs are excluded", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4250/PAN34%20manual-20210713.pdf" } }