{ "manufacturer": "Philio Technology Corp", "manufacturerId": "0x013c", "label": "PAD15", "description": "2 Wire Dimmer", "devices": [ { "productType": "0x0005", "productId": "0x007e", "zwaveAllianceId": [4209, 4216, 4217, 4248, 4256, 4257, 4261, 4264, 4268] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Switch Set", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Enable S1", "value": 0 }, { "label": "Enable S1 & S2", "value": 1 }, { "label": "Dimmer up/down", "value": 2 } ] }, { "#": "2", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on" }, { "#": "3", "label": "Send Multilevel Switch Reports", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "4", "label": "Maximum Level", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 99 }, { "#": "5", "label": "Minimum Level", "valueSize": 1, "minValue": 0, "maxValue": 98, "defaultValue": 0 }, { "#": "6", "label": "Basic Duration Set", "valueSize": 1, "unit": "seconds", "minValue": 0, "maxValue": 127, "defaultValue": 2 } ], "metadata": { "inclusion": "Add(Classic Inclusion) : 1. Put your Z-Wave™ controller into inclusion mode by following the instructions\nprovided by the controller manufacturer. 2. Press the include button three times within 3 seconds to enter\ninclusion mode", "exclusion": "Remove (Exclusion) 1. Put your Z-Wave™ controller into exclusion mode by following the instructions\nprovided by the controller manufacturer. 2. Press the include button three times within 3 seconds to enter\nexclusion mode. 3. Node ID will be excluded", "reset": "Reset : 1. Press the include button four times within 3 seconds and hold on the button press without\nreleasing. 2. Keep pressing the button for 3 seconds then LED will be o ,release the button within 2 seconds.\n3. Device has been reset. ※Function Reset : Please use this procedure only when the network primary\ncontroller is missing or otherwise inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4209/PAD15_UserManual_V3.pdf" } }