{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGWPB-111", "description": "Fibaro Wall Plug", "devices": [ { "productType": "0x1701", "productId": "0x2000" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "2", "label": "PowerFailure", "description": "How the Wall Plug will react in the event of power supply failure", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Off", "value": 0 }, { "label": "Restore", "value": 1 } ] }, { "#": "3", "label": "Overload Safety Switch", "description": "turn off the controlled device in case of exceeding the defined power.", "valueSize": 2, "unit": "0.1 W", "minValue": 0, "maxValue": 18000, "defaultValue": 0 }, { "#": "11", "label": "Power Reporting", "description": "Minimum change in active power consumption to trigger", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 15 }, { "#": "12", "label": "Energy Reporting Threshold", "valueSize": 2, "unit": "0.01 kWh", "minValue": 0, "maxValue": 500, "defaultValue": 10 }, { "#": "13", "label": "Periodic Power Report", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32400, "defaultValue": 3600 }, { "#": "14", "label": "Periodic Energy Report", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32400, "defaultValue": 3600 }, { "#": "15", "label": "SelfConsumption", "description": "Measuring energy consumed by the Wall Plug itself", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Function inactive", "value": 0 }, { "label": "Function active", "value": 1 } ] }, { "#": "21", "label": "UPValue", "description": "UP value -On/Off (Power) association group (3)", "valueSize": 2, "unit": "0.1W", "minValue": 100, "maxValue": 18000, "defaultValue": 500 }, { "#": "22", "label": "DOWNvalue", "description": "lower power threshold", "valueSize": 2, "unit": "0.1w", "minValue": 0, "maxValue": 17900, "defaultValue": 300 }, { "#": "23", "label": "ControlMode", "description": "the way that 3rd association group devices are controlled", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Going up", "value": 1 }, { "label": "Going down", "value": 2 }, { "label": "Both ways", "value": 3 } ] }, { "#": "24", "label": "SwitchOn", "description": "Command sent when physical button is pressed", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "25", "label": "SwitchOff", "description": "Command sent when button turned off.", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0, "readOnly": true }, { "#": "26", "label": "ThresholdUpCmd", "description": "Command sent if power exceeds param 21", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "27", "label": "ThresholdDownCmd", "description": "Command sent when power drops below threshold", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "30", "label": "ActiveAlarm", "description": "Z-Wave network alarms to which the Wall Plug will respond", "valueSize": 1, "defaultValue": 63, "allowManualEntry": false, "options": [ { "label": "General alarm", "value": 1 }, { "label": "Smoke alarm", "value": 2 }, { "label": "CO alarm", "value": 4 }, { "label": "CO2 alarm", "value": 8 }, { "label": "High temp alarm", "value": 16 }, { "label": "Flood alarm", "value": 32 }, { "label": "All", "value": 63 } ] }, { "#": "31", "label": "AlarmResponse", "description": "how the Wall Plug will respond to alarms", "valueSize": 1, "minValue": 0, "maxValue": 50, "defaultValue": 0, "options": [ { "label": "No reaction", "value": 0 }, { "label": "Turn connected device on", "value": 1 }, { "label": "Turn connected device off", "value": 2 } ] }, { "#": "32", "label": "AlarmDuration", "description": "duration of alarm state", "valueSize": 2, "unit": "seconds", "minValue": 1, "maxValue": 32400, "defaultValue": 600 }, { "#": "40", "label": "PwrLoadViolet", "description": "maximum active power value causes the LED frame to flash violet", "valueSize": 2, "unit": "0.1w", "minValue": 1000, "maxValue": 18000, "defaultValue": 18000 }, { "#": "41", "label": "LEDwhenOn", "description": "LED frame color when controlled device is on", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Illumination turned off completely", "value": 0 }, { "label": "Color changes smoothly depending on active power", "value": 1 }, { "label": "Color changes in steps depending on active power", "value": 2 }, { "label": "White", "value": 3 }, { "label": "Red", "value": 4 }, { "label": "Green", "value": 5 }, { "label": "Blue", "value": 6 }, { "label": "Yellow", "value": 7 }, { "label": "Cyan", "value": 8 }, { "label": "Magenta", "value": 9 } ] }, { "#": "42", "label": "LEDwhenOff", "description": "LED frame color when controlled device is off", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Illumination turned off completely", "value": 0 }, { "label": "LED frame is illuminated with last color", "value": 1 }, { "label": "White", "value": 3 }, { "label": "Red", "value": 4 }, { "label": "Green", "value": 5 }, { "label": "Blue", "value": 6 }, { "label": "Yellow", "value": 7 }, { "label": "Cyan", "value": 8 }, { "label": "Magenta", "value": 9 } ] }, { "#": "43", "label": "LEDwhenAlarm", "description": "LED frame color at the Z-Wave network alarm detection", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Illumination turned off completely", "value": 0 }, { "label": "No change in color", "value": 1 }, { "label": "LED frame flashes red/blue/white", "value": 2 }, { "label": "White", "value": 3 }, { "label": "Red", "value": 4 }, { "label": "Green", "value": 5 }, { "label": "Blue", "value": 6 }, { "label": "Yellow", "value": 7 }, { "label": "Cyan", "value": 8 }, { "label": "Magenta", "value": 9 } ] } ] }