{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGSD002", "description": "Smoke Detector", "devices": [ { "productType": "0x0c02", "productId": "0x1002" }, { "productType": "0x0c02", "productId": "0x1003" }, { "productType": "0x0c02", "productId": "0x4002" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Smoke Sensor Sensitivity", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "High", "value": 1 }, { "label": "Medium", "value": 2 }, { "label": "Low", "value": 3 } ] }, { "#": "2", "label": "Z-Wave Notifications Status", "description": "This parameter allows to activate excess temperature ...", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "3", "label": "Visual Indicator Notifications Status", "description": "This parameter allows to activate visual indications", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "All notifications disabled", "value": 0 }, { "label": "Enclosure opening notification enabled", "value": 1 }, { "label": "Exceeding temp threshold notification enabled", "value": 2 }, { "label": "Enclosure opening notification enabled +", "value": 3 }, { "label": "Lack of Z-Wave range notification", "value": 4 }, { "label": "Enclosure opening notification enabled and", "value": 5 }, { "label": "Exceeding temp threshold notification enabled +", "value": 6 }, { "label": "Enclosure opening notification enabled +", "value": 7 } ] }, { "#": "4", "label": "Sound Notifications Status", "description": "This parameter allows to activate sound signals...", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "All notifications disabled", "value": 0 }, { "label": "Enclosure opening notification enabled", "value": 1 }, { "label": "Exceeding temp threshold notification enabled", "value": 2 }, { "label": "Enclosure opening notification enabled +", "value": 3 }, { "label": "Lack of Z-Wave range notification", "value": 4 }, { "label": "Enclosure opening notification enabled +", "value": 5 }, { "label": "Exceeding temp threshold notification enabled +", "value": 6 }, { "label": "Enclosure opening notification enabled and", "value": 7 } ] }, { "#": "10", "label": "Config of Control Frames in Basic Command Class", "description": "This parameter defines which frames will be sent ...", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Basic on and basic off enabled", "value": 0 }, { "label": "Basic on enabled", "value": 1 }, { "label": "Basic off enabled", "value": 2 } ] }, { "#": "11", "label": "BASIC ON Frame Value", "description": "BASIC ON frame is sent in case of smoke presence detection ...", "valueSize": 2, "minValue": 1, "maxValue": 255, "defaultValue": 255 }, { "#": "12", "label": "BASIC OFF Frame Value", "description": "BASIC OFF frame is sent in case of FIRE ALARM cancellation.", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "13", "label": "Alarm Broadcast", "description": "A value other than 0 means that alarms are being ...", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Broadcast inactive", "value": 0 }, { "label": "Fire alarm broadcast 2nd/4th association group", "value": 1 }, { "label": "Fire alarm broadcast 2nd/4th association group", "value": 2 }, { "label": "Fire alarm broadcast 2nd/4th association group", "value": 3 } ] }, { "#": "14", "$if": "firmwareVersion >= 3.2", "label": "Associations in Z-Wave Network Security Mode", "valueSize": 1, "minValue": 0, "maxValue": 15, "defaultValue": 15 }, { "#": "20", "label": "Temperature Report Interval", "description": "Time interval between consecutive temperature reports.", "valueSize": 2, "minValue": 0, "maxValue": 8640, "defaultValue": 1 }, { "#": "21", "label": "Temperature Report Hysteresis", "description": "The temperature report will only be sent if there is a difference ...", "valueSize": 1, "minValue": 1, "maxValue": 100, "defaultValue": 10 }, { "#": "30", "label": "Temperature Threshold", "description": "Temperature threshold for activating alarms", "valueSize": 1, "minValue": 1, "maxValue": 100, "defaultValue": 55 }, { "#": "31", "label": "Excess Temperature Signaling Interval", "description": "Time interval of signaling (visual indication/sound) excess ...", "valueSize": 2, "minValue": 1, "maxValue": 8640, "defaultValue": 1 }, { "#": "32", "label": "Lack of Z-Wave Range Indication Interval", "description": "Time interval of signaling (visual indication/sound) lack of ...", "valueSize": 2, "minValue": 1, "maxValue": 8640, "defaultValue": 180 } ] }