{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGS213", "description": "Single Switch 2", "devices": [ { "productType": "0x0403", "productId": "0x1000" }, { "productType": "0x0403", "productId": "0x2000" }, { "productType": "0x0403", "productId": "0x3000" }, { "productType": "0x0403", "productId": "0x4000" }, { "productType": "0x0403", "productId": "0x6000" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "9", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "10", "label": "First Channel Operating Mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Standard operation", "value": 0 }, { "label": "Delay on", "value": 1 }, { "label": "Delay off", "value": 2 }, { "label": "Auto on", "value": 3 }, { "label": "Auto off", "value": 4 }, { "label": "Flashing mode", "value": 5 } ] }, { "#": "11", "label": "1st Ch. Reaction to Switch", "description": "First channel - reaction to switch for delay/auto ON/OFF modes", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Cancel mode and set target state", "value": 0 }, { "label": "No reaction to switch - Mode runs until it ends", "value": 1 }, { "label": "Reset timer - Start counting from the beginning", "value": 2 } ] }, { "#": "12", "label": "First Channel - Time Parameter for Delay/auto ON/OFF Modes", "valueSize": 2, "minValue": 0, "maxValue": 32000, "defaultValue": 50 }, { "#": "13", "label": "First Channel - Pulse Time for Flashing Mode", "valueSize": 2, "minValue": 1, "maxValue": 32000, "defaultValue": 5 }, { "#": "20", "label": "Switch Type", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Momentary switch", "value": 0 }, { "label": "Toggle switch stable", "value": 1 }, { "label": "Toggle switch", "value": 2 } ] }, { "#": "21", "label": "Flashing Mode - Reports", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "The device does not send reports", "value": 0 }, { "label": "The device sends reports", "value": 1 } ] }, { "#": "27", "label": "Associations in Z-Wave Network Security Mode", "valueSize": 1, "defaultValue": 15, "allowManualEntry": false, "options": [ { "label": "No group sent as secure", "value": 0 }, { "label": "2nd group sent as secure", "value": 1 }, { "label": "3rd group sent as secure", "value": 2 }, { "label": "4th group sent as secure", "value": 4 }, { "label": "5th group sent as secure", "value": 8 }, { "label": "All groups sent as secure", "value": 15 } ] }, { "#": "28", "label": "S1 Switch - Scenes Sent", "valueSize": 1, "minValue": 0, "maxValue": 15, "defaultValue": 0, "options": [ { "label": "No scenes sent", "value": 0 }, { "label": "Key pressed 1 time", "value": 1 }, { "label": "Key pressed 2 times", "value": 2 }, { "label": "Key pressed 3 times", "value": 4 }, { "label": "Key hold down and key released", "value": 8 } ] }, { "#": "29", "label": "S2 Switch - Scenes Sent", "valueSize": 1, "minValue": 0, "maxValue": 15, "defaultValue": 0, "options": [ { "label": "No scenes sent", "value": 0 }, { "label": "Key pressed 1 time", "value": 1 }, { "label": "Key pressed 2 times", "value": 2 }, { "label": "Key pressed 3 times", "value": 4 }, { "label": "Key hold down and key released", "value": 8 } ] }, { "#": "30", "label": "S1 Assocs. Sent to 2nd and 3rd Group", "valueSize": 1, "minValue": 0, "maxValue": 15, "defaultValue": 0, "options": [ { "label": "All actions are active by default", "value": 0 }, { "label": "Ignore turning on with 1 click of the switch", "value": 1 }, { "label": "Ignore turning off with 1 click of the switch", "value": 2 }, { "label": "Ignore holding and releasing the switch", "value": 4 }, { "label": "Ignore double click of the switch", "value": 8 } ] }, { "#": "31", "label": "S1 ON Val Sent to 2nd and 3rd Groups", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "32", "label": "S1 OFF Val Sent to 2nd and 3rd Groups", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "33", "label": "S1 DblClick Val Sent to 2nd and 3rd Groups", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 99 }, { "#": "35", "label": "S2 Assocs. Sent to 4th and 5th Group", "valueSize": 1, "minValue": 0, "maxValue": 15, "defaultValue": 0, "options": [ { "label": "All actions are active by default", "value": 0 }, { "label": "Ignore turning on with 1 click of the switch", "value": 1 }, { "label": "Ignore turning off with 1 click of the switch", "value": 2 }, { "label": "Ignore holding and releasing the switch", "value": 4 }, { "label": "Ignore double click of the switch", "value": 8 } ] }, { "#": "36", "label": "S2 Switch ON Value Sent to 4th and 5th Ass. Groups", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "37", "label": "S2 Switch OFF Sent to 4th and 5th Groups", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "38", "label": "S2 Double Click Sent to 4th and 5th Association Groups", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 99 }, { "#": "40", "label": "Reaction to General Alarm", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Ignore", "value": 0 }, { "label": "Turn on", "value": 1 }, { "label": "Turn off", "value": 2 }, { "label": "Flash", "value": 3 } ] }, { "#": "41", "label": "Reaction to Flood Alarm", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Ignore", "value": 0 }, { "label": "Turn on", "value": 1 }, { "label": "Turn off", "value": 2 }, { "label": "Flash", "value": 3 } ] }, { "#": "42", "label": "Reaction to CO/CO2/Smoke Alarm", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Ignore", "value": 0 }, { "label": "Turn on", "value": 1 }, { "label": "Turn off", "value": 2 }, { "label": "Flash", "value": 3 } ] }, { "#": "43", "label": "Reaction to Heat Alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Ignore", "value": 0 }, { "label": "Turn on", "value": 1 }, { "label": "Turn off", "value": 2 }, { "label": "Flash", "value": 3 } ] }, { "#": "44", "label": "Flashing Alarm Duration", "valueSize": 2, "minValue": 1, "maxValue": 32000, "defaultValue": 600 }, { "#": "50", "label": "Active Power Reports", "description": "Power level reporting threshold.", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 20 }, { "#": "51", "label": "Minimal Time Between Power Report", "valueSize": 1, "minValue": 0, "maxValue": 120, "defaultValue": 10 }, { "#": "53", "label": "Energy Reports", "description": "Energy level change resulting in sending a new energy report.", "valueSize": 2, "minValue": 0, "maxValue": 32000, "defaultValue": 100 }, { "#": "58", "label": "Periodic Power Reports", "description": "Determines time interval for periodic power reports", "valueSize": 2, "minValue": 0, "maxValue": 32000, "defaultValue": 3600 }, { "#": "59", "label": "Periodic Energy Reports", "description": "Determines time interval for periodic energy reports", "valueSize": 2, "minValue": 0, "maxValue": 32000, "defaultValue": 3600 }, { "#": "60", "label": "Measuring Energy Consumed by the Device Itself", "description": "Determines if energy consumed by device should be included", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Self-Measurement inactive", "value": 0 }, { "label": "Self-Measurement active", "value": 1 } ] } ] }