{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGS212", "description": "Relay Switch 1x2.5kW", "devices": [ { "productType": "0x0401", "productId": "0x100a" }, { "productType": "0x0402", "productId": "0x1002" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Switch 1", "maxNodes": 16 }, "2": { "label": "Switch 2", "maxNodes": 16 }, "3": { "label": "Controller Updates", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Enable/Disable ALL ON/OFF", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "All on disabled / All off disabled", "value": 0 }, { "label": "All on disabled / All off active", "value": 1 }, { "label": "All on active / All off disabled", "value": 2 }, { "label": "All on active / All off active", "value": 255 } ] }, { "#": "3", "label": "Override OFF-Delay", "description": "Forced auto off period", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Turn off with push button disabled", "value": 0 }, { "label": "Turn off with push button enabled", "value": 1 } ] }, { "#": "4", "label": "Relay 1: OFF-Delay Time (100ms Steps)", "description": "Automatic turning off relay 1 after set time ...", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "6", "label": "Separation of Association Sending (Key 1)", "description": "Sending commands to control devices assigned ...", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Map status to all devices in group 1", "value": 0 }, { "label": "Map off status to all devices in group 1", "value": 1 }, { "label": "Map off status to all devices in group 1", "value": 2 } ] }, { "#": "13", "label": "Inputs Behaviour", "description": "Assigns bistable key status to the device status.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Toggle", "value": 0 }, { "label": "Follow switch contact (Closed=ON, open=OFF)", "value": 1 } ] }, { "#": "14", "label": "Inputs Button/Switch Configuration", "description": "Binary inputs type configuration", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Mono-Stable input (Button)", "value": 0 }, { "label": "Bi-Stable input (Switch)", "value": 1 } ] }, { "#": "15", "label": "Dimmer/Roller Shutter Control", "description": "Enable/Disable operation of dimmer or roller shutter devices ...", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disable dimmer/roller shutter control", "value": 0 }, { "label": "Enable dimmer/roller shutter control", "value": 1 } ] }, { "#": "16", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "30", "label": "Relay 1: Response to General Alarm", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Deactivation - No response to alarm frames", "value": 0 }, { "label": "Alarm relay on", "value": 1 }, { "label": "Alarm relay off", "value": 2 }, { "label": "Alarm flashing - Relay will turn on and off", "value": 3 } ] }, { "#": "31", "label": "Relay 1: Response to Water Flood Alarm", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Deactivation - No response to alarm frames", "value": 0 }, { "label": "Alarm relay on", "value": 1 }, { "label": "Alarm relay off", "value": 2 }, { "label": "Alarm flashing - Relay will turn on and off", "value": 3 } ] }, { "#": "32", "label": "Relay 1: Response to Smoke, CO, CO2 Alarm", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Deactivation - No response to alarm frames", "value": 0 }, { "label": "Alarm relay on", "value": 1 }, { "label": "Alarm relay off", "value": 2 }, { "label": "Alarm flashing - Relay will turn on and off", "value": 3 } ] }, { "#": "33", "label": "Relay 1: Response to Temperature Alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Deactivation - No response to alarm frames", "value": 0 }, { "label": "Alarm relay on", "value": 1 }, { "label": "Alarm relay off", "value": 2 }, { "label": "Alarm flashing - Relay will turn on and off", "value": 3 } ] }, { "#": "39", "label": "ALARM FLASHING Alarm Time", "description": "Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 600, "unsigned": true } ], "compat": { // The device sends reports for endpoint 1 un-encapsulated "mapRootReportsToEndpoint": 1 } }