{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGRM222", "description": "Roller Shutter", "devices": [ { "productType": "0x0301", "productId": "0x1001" }, { "productType": "0x0301", "productId": "0x3001" }, { "productType": "0x0302", "productId": "0x1000" } ], "firmwareVersion": { "min": "0.0", "max": "24.23" }, "associations": { "1": { "label": "Momentary click", "maxNodes": 16 }, "2": { "label": "Momentary hold", "description": "Only applies to momentary switches", "maxNodes": 16 }, "3": { "label": "Controller Updates", "maxNodes": 1, "isLifeline": true } }, "proprietary": { "fibaroCCs": [38 /* 0x26 (Venetian Blinds) */] }, "paramInformation": [ { "#": "3", "label": "Reports Type", "description": "Enable Venetian Blind mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Blind position reports sent using Z-Wave commands", "value": 0 }, { "label": "Blind position reports sent using Fibaro commands", "value": 1 } ] }, { "#": "10", "label": "Roller Shutter Operating Modes", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Roller blind mode, without positioning", "value": 0 }, { "label": "Roller blind mode, with positioning", "value": 1 }, { "label": "Venetian blind mode, with positioning", "value": 2 }, { "label": "Gate mode, without positioning", "value": 3 }, { "label": "Gate mode, with positioning", "value": 4 } ] }, { "#": "12", "label": "Turning Time/delay Time", "description": "Time of full turn of the lamellas.", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 150, "unsigned": true }, { "#": "13", "label": "Lamellas Positioning Mode", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Only in case of the main controller operation", "value": 0 }, { "label": "Controller, switch or limit switch operation", "value": 1 }, { "label": "Controller, switch, limit sw operation/stop frame", "value": 2 } ] }, { "#": "14", "label": "Switch Type", "description": "Parameter settings for Roller and Venetian Blind Mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Momentary switches", "value": 0 }, { "label": "Toggle switches", "value": 1 }, { "label": "Single, momentary switch", "value": 2 } ] }, { "#": "17", "label": "Delay Time After S2", "description": "Relays turn off time after reaching a limit switch.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true }, { "#": "18", "label": "Motor Operation Detection", "description": "Power threshold to be interpreted as reaching a limit switch.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true }, { "#": "22", "label": "Motor Operation Time", "description": "Time period for the motor to continue operation.", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 10, "unsigned": true }, { "#": "29", "label": "Forced Roller Shutter Calibration", "description": "Roller Shutter enters the calibration mode.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Deactivated", "value": 0 }, { "label": "Start calibration process", "value": 1 } ] }, { "#": "30", "label": "Response to General Alarm", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "31", "label": "Response to Water Flood Alarm", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "32", "label": "Response to Smoke, CO, CO2 Alarm", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "33", "label": "Response to Temperature Alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "35", "label": "Managing Lamellas in Response to Alarm", "description": "Lamellas reaction upon alarm detection.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Do not change lamellas position", "value": 0 }, { "label": "Set lamellas to their extreme position", "value": 1 } ] }, { "#": "40", "label": "Power Reports", "description": "Power level change resulting in new power value report", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 10 }, { "#": "42", "label": "Periodic Power or Energy Reports", "description": "Time to the next report. Value of 0 means the reports are turned off.", "valueSize": 2, "minValue": -32767, "maxValue": 32767, "defaultValue": 3600 }, { "#": "43", "label": "Energy Reports", "description": "Energy level change resulting in new energy value report", "valueSize": 1, "minValue": -126, "maxValue": 127, "defaultValue": 10 }, { "#": "44", "label": "Self-Measurement", "description": "Enables/disables power and energy report used by itself", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Activated", "value": 1 } ] }, { "#": "50", "label": "Scenes/Associations Activation", "description": "Determine whether scenes or associations are activated", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Associations active", "value": 0 }, { "label": "Scenes active", "value": 1 } ] } ], "compat": { "commandClasses": { "add": { // The device can be controlled using Multilevel Switch CC, but it does not advertise it. "Multilevel Switch": { "isSupported": true, "version": 2 } }, // The device exposes Binary Switch CC, but Multilevel Switch CC supersedes it "remove": { "Binary Switch": { "endpoints": "*" } } } } }